75
Login Message
When a login message is set, comments can be put on the data of the
splice history automatically. When the state of “Login message” is active,
Setting screen is displayed like figure just after turning on the power.
When changing the comment, set characters
by
◄
►
, ▲ ▼ keys and Set key. The set
comment is preserved in splice history data
as “CMNT”.
Sensor
『 Active ⇔ Cancel 』
Active
Depending on the change in barometric pressure of the
environment, the arc discharge power is corrected
automatically.
Cancel
Cancel auto correction.
Real Time Arc Control
Activate Real Time Arc Control.
『Cancel ⇔ Active』
Zoom Image
The fiber image is centered at the brief stop before arc discharge.
『Cancel ⇔ Active』
Display Image
Activating fiber image during arc discharging
『Type 1 ⇔ Type 2』