8.2.7 Parameter table
Parameter Table for Splice
Parameter Name Min Max
Description
1
st
Arc Start Power
0
200 Starting arc power in 1
st
arc
discharge
1
st
Arc End Power
0
200 Ending arc power in 1
st
arc discharge
2
nd
Arc Start Power
0
200 Starting arc power in 2
nd
arc
discharge
2
nd
Arc End Power
0
200 Ending arc power in 2
nd
arc
discharge
Cleaning Arc
Power Offset
-127 128 Additional Arc Power for cleaning
purposes
Cleaning Duration
0
32767 Arc duration for cleaning [msec]
Pre-fuse Duration
0
32767 Time between arc starting and fibers
first butting [msec]
1
st
Arc Duration
0
32767 1st arc time duration [msec]
2
nd
Arc Duration
0
32767 2nd arc time duration [msec]
Z Pull Start Time
[ms]
0
32767 Time to start to pull back the fiber
[msec]
Z Push Distance
[µm]
0
32767 Overlapping distance from fibers
first butting position [µm]
Z Pull Distance
[µm]
0
32767 Pulling back distance from the final
overlapping position [µm]
Re Arc Times
[times]
0
255
Allowable numbers for the repeat
arc in programmed additional arc
mode
Re Arc Duration
[ms]
0
32767 Duration of additional arc [msec]
Re Arc Interval
[ms]
0
32767 Interval between additional arc and
additional arc [msec]
Repeat Arc Power
Offset
-127 128 Power of additional arc is Arc Power
added by Repeat Arc Power Offset
Re Arc Power
0
255 Power of additional arc
Gap [µm]
0
184 Gap for the final position tuning