63
Measuring Results
The results are shown as in the pictures.
The following parameters are measured. Press ▲▼ keys to change the
parameters.
Sample
Description
CLAD OFF
Amount of CLAD OFFSET between the two fibers [µm]
ANGLE L
Cleave angle of the left fiber [degree]
ANGLE R
Cleave angle of the right fiber [degree]
REL.ANGLE
RELATIVE cleave angle between the two fibers [degree]
GAP
GAP between the two fibers [µm]
CLAD W L
Clad width of the left fiber [µm]
CLAD W R
Clad width of the right fiber [µm]
TILT L
Tilt angle of the left fiber clad center [degree]
TILT R
Tilt angle of the right fiber clad center [degree]
8.4.3 Environment
The NJ001 allows the user to view environmental conditions.
1.
Select “Environment” in the Tool menu screen and press Enter.
2.
“Temperature” and Ambient “Pressure”
are displayed. Press °C<=>F key to
convert the temperature unit.
3.
Press Escape to return to the previous
screen.