27
The NJ001 Fusion Splicer is installed with the factory-set Heat Programs as
follows.
No. Mode
Comment
Description
1
40MM
S922
Furukawa S922 sleeve (40mm)
2
40MM
S922 POWER Furukawa S922 sleeve (40mm) with
pre-heating.*
3
40MM
OTHER
Other 40mm length sleeve
4
40MM
SMOUV
POWER
TE connectivity SMOUV-02 sleeve
(40mm) with pre-heating.*
5
----
---
Vacant
6
----
---
Vacant
7
60MM
S921
Furukawa S921 sleeve (60mm)
8
60MM
S921 POWER Furukawa S921 sleeve (60mm) with
pre-heating *
9
60MM
OTHER
Other 60mm length sleeve
10
60MM
SMOUV
POWER
TE connectivity SMOUV-01 sleeve
(60mm) with pre-heating.*
11
60MM
CONTINUOUS Heating continuously for 60mm
12
----
---
Vacant
13
40MM
S924
Furukawa S924 sleeve (40mm)
14
40MM
S924 POWER Furukawa S924 sleeve (40mm) with
pre-heating *
15
40MM
S927B
Furukawa S927B sleeve (40mm)
16
40MM S927B POWER Furukawa S927B sleeve (40mm) with
pre-heating *
17
MINI
S928A
Furukawa S928A sleeve
(20/25/30mm length)
18
MINI
OTHER
Other 20/25/30mm length sleeve
19
:
27
28
60MM
S921DC
Furukawa S921DC sleeve (60mm)
29
---
SOC
20mm length sleeve for SOC
30
---
CURL REMOVE Removing giber curl
*) Pre-heating warms the heater to shorten the heating time in advance, before the