53
Parameter Table for Heater Program
Parameter
Min Max
Description
1
st
Heat Temp IN
[deg C]
0
280 Temperature of INNER heater for the
first half.
1
st
Heat Temp OUT
[deg C]
0
280 Temperature of OUTER heater for the
first half.
1
st
Heat Time [sec] 0
300 Operation time of the first half.
2
nd
Heat Temp IN
[deg C]
0
280 Temperature of INNER heater for The
latter half.
2
nd
Heat Temp
OUT [deg C]
0
280 Temperature of OUTER heater for The
latter half.
2
nd
Heat Time
[sec]
0
300 Heating time after 1
st
heating
Cool Temp [deg C] 0
280 Temperature to arrive at end of cooling
process.
Pre Heat temp IN
[deg C]
0
280
Temperature of INNER heater for
preliminary heating. Preliminary
heating temperature before the first
half.
Pre Heat temp
OUT [deg C]
0
280
Temperature of OUTER heater for
preliminary heating. Preliminary
heating temperature before the first
half.
Pre Heat Time
[sec]
0
300
Operation time of preliminary heating
after the end of cooling process or
before the first half.
Auto Start
0
2
Setting for automatic start function.
[0] : Manual start operation.
[1] : When fiber set and left clamping
is shut, heating start automatically.*
[2]: Consecutive heating operation.
Compensation
Auto Start
0
30 Expansion time of the automatic
operation.
*Do not leave the protection sleeve in a heater after finish of shrinkage.
The coating may melt.