56
Data Title
Description
CMNT
Comment of the data, which can be edited.
No.
No. 1 is the data for the last splice and the number
increases for older splices.
Arc Count
Arc Count when splice was performed.
Date
Date and time for the splice performed.
Env.
The environmental temperature and the air pressure,
when Splicing was done.
PRGM
Name of Fusion Program.
Arc Power
Value of the strength of the electric discharge when
splicing
Retreat
Retreat value in arc check
Center
Retreat center position in arc check
Loss
Estimated splice loss
AngL
Cleave angle of the left fiber
AngR
Cleave angle of the right fiber
Axis
Axis offset before splice
Note
Error codes and additional arc memo if any. The data with
error is highlighted.
L: Estimated loss exceeds the target value
S: Streak or bubble at the splice point or not spliced
A: Cleave angle exceeds the criteria
C: Cleave end face has excessive defects
G: Gap difference exceeds the criteria
+: Additional arc is applied
4.
Press Menu and the pop-up shows available functions. Select desired
function and press Enter to initiate the operation.
Edit Comment: Edit the Comment of data.
PC-OUT: Transfer/Uploading the data to PC.
Delete: Delete the data.