Appendix A
Fixed Issues
75
Fujitsu 4Gbps Fibre Channel Card Is Falsely
Recognized as F20 Card (CR 6947945)
This issue is resolved by updating the system firmware to 7.2.10 or later.
When you mount a Fujitsu 4Gbps Fibre Channel card and start the system, the
4Gbps Fibre Channel card is falsely recognized as a F20 card in the ILOM CLI
interface. Also, the slot number is falsely displayed. In addition, the false
recognition and the false display may occur also in the FRU Status of the
prtdiag
-v
command output.
Shown below is an event example in time of failure.
Configuration:
PCIE#0: Fibre Channel card
PCIE#1: void
PCIE#2: void
PCIE#3: void
PCIE#4: void
PCIE#5: void
The ILOM CLI interface output example:
PCIE5
PCIE
FJSV,e4ta-fjgi
Broadcom,BCM5704C
/pci@500/pci@0/pci@c/pci@0/pci@9/pci@0/pci@1/pci@0/FJSV,e4ta@4,1
PCIE5
PCIE
FJSV,e4ta-fjgi
Broadcom,BCM5704C
/pci@500/pci@0/pci@c/pci@0/pci@9/pci@0/pci@1/pci@0,1/FJSV,e4ta@6
PCIE5
PCIE
FJSV,e4ta-fjgi
Broadcom,BCM5704C
/pci@500/pci@0/pci@c/pci@0/pci@9/pci@0/pci@1/pci@0,1/FJSV,e4ta@6,1
PCIE5
PCIE
FJSV,e2ta-fjgi
Broadcom,BCM5715C
/pci@500/pci@0/pci@c/pci@0/pci@9/pci@0/pci@9/pci@0/FJSV,e2ta@4
PCIE5
PCIE
FJSV,e2ta-fjgi
Broadcom,BCM5715C
/pci@500/pci@0/pci@c/pci@0/pci@9/pci@0/pci@9/pci@0/FJSV,e2ta@4,1
...
/SYS/MB/RISER1/PCIE1/F20CARD
Properties:
type = F20 Card
ipmi_name = RSR1/PCIE1/F20
fault_state = OK
clear_fault_action = (none)
Summary of Contents for SPARC Enterprise T5440 Server
Page 4: ......
Page 18: ...8 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 38: ...28 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 58: ...48 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 66: ...56 SPARC Enterprise T5440 Server Product Notes December 2010 ...