![background image](http://html.mh-extra.com/html/fujitsu/sparc-enterprise-t5440-server/sparc-enterprise-t5440-server_user-manual_121367040.webp)
30
SPARC Enterprise T5440 Server Product Notes • December 2010
Hardware and Mechanical Issues
This section describes hardware issues known to exist at this release of the SPARC
Enterprise T5440 server.
TABLE 3-1
Hardware and Mechanical Issues
CR ID
Description
Workaround
n/a
Some PCIe cards do not have enough clearance
for external cables when installed in PCIe Slot 7.
The cable management arm (CMA) release
button may interfere with external cables and/or
connectors for the following PCIe cards when
installed in PCIe Slot 7:
• XVR-300 frame buffer card
• Any PCIe card with an external SCSI
connector
• Any PCIe card with an external fiber cable
connector
Do one of the following:
• Install the restricted cards in a slot other than
PCIe Slot 7
• Do not install the cable management arm
6706976
At write to CD/DVD media, there may be cases
where the writing speed may not reach the
maximum speed supported by the CD/DVD
drive.
Even if the maximum operation is not reached,
there are no problems in the processing for
writing to the CD/DVD media.
Use the media as is.
n/a
XAUI card disables an On-board network port.
For details, see
Disabled by an XAUI Card” on page 31
.
6679425
PCIe Slots 4 and 7 have tight clearances with the
chassis rear panel.
When installing a PCIe card in PCIe Slot 4 or 7,
angle the card to clear the tab on the PCIe latch
on the chassis rear panel, then insert the card
vertically into the PCIe slot on the motherboard.
6726637
If three or four USB thumb drives are connected
to the external USB ports, and the system is
under heavy I/O load (including on the USB
thumb drives), the system might panic after
several hours (typically more than 10).
Under heavy I/O load, do not connect more
than two USB thumb drives to the system.
Summary of Contents for SPARC Enterprise T5440 Server
Page 4: ......
Page 18: ...8 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 38: ...28 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 58: ...48 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 66: ...56 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 92: ...82 SPARC Enterprise T5440 Server Product Notes December 2010 ...