Appendix A
Fixed Issues
59
If
prtdiag
Is Canceled, Subsequent
prtdiag
Executions May Fail to Display Status Information
(CR 6552999, 6731560)
This issue is resolved with Solaris patch ID 138082-01 or later, and 139502-02 or later.
If the verbose (
-v
) option is specified for the control domain
prtdiag
command,
additional environmental status information will be displayed. If
Control-C
is
issued to interrupt the output of this information, the picld(1M) daemon may enter
the state in which environmental status information is no longer supplied to
prtdiag
. If it does, additional environmental data will no longer be displayed.
Workaround: The following command restarts the picld SMF service. If
prtdiag -v
or
prtpicl
fails to display status information, wait for several minutes, and then
retry or restart picl. Execute
prtdiag -v
about 10 minutes after picl is restarted.
■
Method 1: restarting picl
# svcadm restart picl
Wait for several minutes.
#
prtdiag -v
■
Method 2: stopping and restarting
# svcadm disable svc:/system/picl:default
# rm -rf /var/run/picld_door
# svcadm enable svc:/system/picl:default
6734788
6784914
During the system operation, a panic may occur
with the PCIEX-8000-6D message output.
This occurs more frequently with a high-load
access to the CD/DVD/USB device; however,
even if the DVD drive is not used, vold(1M) of
Solaris OS is accessing to the DVD drive
periodically, and a panic may occur on rare
occasions.
Note - Fixed in System Firmware 7.2.10.a or
later.
Use the DVD drive only to install the OS or
software or apply a patch or program temporary
fix (PTF).
And stop vold(1M) if the system is running. Stop
of vold(1M) doesn't disrupt the system
operation.
To stop vold(1M), disable the volfs service,
which is a SMF service.
#
svcadm disable volfs
To use removable devices such as DVD, execute
the following.
#
svcadm enable volfs
TABLE A-2
Fixed Solaris OS Issues
(Continued)
CR ID
Description
Workaround
Summary of Contents for SPARC Enterprise T5440 Server
Page 4: ......
Page 18: ...8 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 38: ...28 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 58: ...48 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 66: ...56 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 92: ...82 SPARC Enterprise T5440 Server Product Notes December 2010 ...