6
SPARC Enterprise T5440 Server Product Notes • December 2010
The
showenvironment
command output example:
Workaround:
None. Reset ILOM to recover. If the error is cleared, then it corresponds to this event
and the fan replacement is unnecessary. ILOM reset has no impact on the system.
/SYS/FANBD0/FM0/F0/TACH FAILED 0 4000 2400
/SYS/FANBD0/FM0/F1/TACH FAILED 0 4000 2400
/SYS/FANBD0/FM1/F0/TACH FAILED 0 4000 2400
/SYS/FANBD0/FM1/F1/TACH OK 6400 4000 2400
/SYS/FANBD0/FM2/F0/TACH OK 7000 4000 2400
/SYS/FANBD0/FM2/F1/TACH FAILED 0 4000 2400
sc>
showfaults
Last POST Run: Mon Jul 12 00:08:46 2010
Post Status: Passed all devices
ID FRU Fault
1 /SYS/FANBD0/FM0 SP detected fault:
TACH at /SYS/FANBD0/FM0/F0 has reached low non-recoverable threshold.
2 /SYS/FANBD0/FM0 SP detected fault:
TACH at /SYS/FANBD0/FM0/F1 has reached low non-recoverable threshold.
3 /SYS/FANBD0/FM1 SP detected fault:
TACH at /SYS/FANBD0/FM1/F0 has reached low non-recoverable threshold.
4 /SYS/FANBD0/FM2 SP detected fault:
TACH at /SYS/FANBD0/FM2/F1 has reached low non-recoverable threshold.