Appendix A
Fixed Issues
71
If this problem occurs, restore normal system operation by using the following
procedure:
1. Disconnect the power cable.
2. Connect the LAN cable to the ILOM network port.
Verify that the ILOM network port is linked up.
3. Connect the power cable.
After the SCC Module Replacement, a Connection
to the ILOM Network May Fail (CR 6857271)
This issue is resolved by updating the system firmware to 7.2.7.b or later.
During SCC module replacement, part (*1) of the data kept on the motherboard is
inadvertently overwritten with new SCC module data (*2). This results in a
connection failure to the ILOM network.
(*1) SCC module data including ILOM user data, network setting data, and
diagnostics data. For details, see the ILOM Supplement for each server.
(*2) The data is initialized at this point in time, so the data has no set values.
Also, the following type of log is output (*) to the ILOM serial console window at
the occurrence of the failure. sccd fails to start at ILOM startup:
Example of output to ILOM serial console at failure occurrence:
SUNSP-BEL07482AU login:
root
Password:
Waiting for daemons to initialize...
Timed out waiting for daemons to start
<-- (*2)
sccd daemon has shutdown
<-- (*2)
Integrated Lights Out Manager
Version 3.0.3.20.e
Copyright 2009 Sun Microsystems, Inc. All rights reserved.
Use is subject to license terms.
Warning: password is set to factory default.
->
Summary of Contents for SPARC Enterprise T5440 Server
Page 4: ......
Page 18: ...8 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 38: ...28 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 58: ...48 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 66: ...56 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 92: ...82 SPARC Enterprise T5440 Server Product Notes December 2010 ...