Chapter 3
Known Issues
47
6699494
Under rare conditions, the system might panic if
repeated commands of creating and deleting
aggregation links are put in a loop and are
executed many times.
Avoid adding, deleting and repeating the link
aggregation operations over and over again.
6724125
When CMP modules are removed but the
corresponding memory modules are left in
place, the service processor reports the
following:
Fault | Critical: /SYS/MB/... prom
is unreadable or corrupted
.
Do not power on the system unless complete
CMP/memory module pairs are installed.
Check for the availability of a patch for this
defect.
6772876
In certain circumstances, if a disabled CMP
module is replaced before the fault is cleared,
the replaced CMP module might not be
recognized by the system.
For example, after replacing CMP1, the ALOM
compatibility shell
showcomponent
command
might not show the following devices:
/SYS/MB/CPU1/CMP1/P0
/SYS/MB/CPU1/CMP1/P1
/SYS/MB/CPU1/CMP1/P2
/SYS/MB/CPU1/CMP1/P3
/SYS/MB/CPU1/CMP1/P4
/SYS/MB/CPU1/CMP1/P5
Reset the service processor after replacing a
faulty CMP module. Type:
sc>
resetsc
TABLE 3-5
Firmware and General Software Issues
(Continued)
CR ID
Description
Workaround
Summary of Contents for SPARC Enterprise T5440 Server
Page 4: ......
Page 18: ...8 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 38: ...28 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 58: ...48 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 66: ...56 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 92: ...82 SPARC Enterprise T5440 Server Product Notes December 2010 ...