background image

UM_J4078-01_v1.3_040819

J4078-01

SAS 12Gb/s JBOD Series

User's Manual

Summary of Contents for J4078-01

Page 1: ...UM_J4078 01_v1 3_040819 J4078 01 SAS 12Gb s JBOD Series User s Manual ...

Page 2: ... Disk Drive Optional 13 2 2 4 Removing and Installing the HDD Tray 14 2 3 Removing and Installing the Power Supply Unit Module 15 2 3 1 Installing the Power Supply Unit 15 2 3 2 Removing the Power Supply Unit 15 2 4 Removing and Installing the Fan Module 16 2 4 1 Installing the Fan 16 2 4 2 Removing the Fan 16 2 5 Removing and Installing the Expander Module 17 2 5 1 Installing the Expander 17 2 5 ...

Page 3: ...DGE only 35 4 3 2 5 How to configure wide port checker 36 4 3 2 6 How to power off on all disk drives automatically 36 4 3 2 7 How to configure EDFB EDGE only 37 4 3 2 8 How to configure power setting HUB only 37 4 3 2 9 How to configure zone count 38 4 3 2 10 How to configure zoning of the wide port HUB only 43 4 3 2 11 How to configure zoning of the disk slot EDGE only 43 4 3 3 SES Inband Featur...

Page 4: ... 4 5 6 SMTP 82 4 4 5 7 Schedule Power ON OFF 84 4 4 5 8 User 86 4 4 6 Remote Control 87 4 4 6 1 Storage power control 87 4 4 6 2 Zone Settings 88 4 5 BMC Firmware Update 90 4 5 1 Requirement 90 4 5 2 Web update 90 4 5 3 Image Transfer Protocol 95 4 6 Expander Firmware MFG Update 96 Chapter 5 Technical Support 102 Contents ...

Page 5: ...Copyright 2018 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements ...

Page 6: ...lease History Release Date Version Update Content July 2018 1 Release to public October 2018 1 1 1 Update BMC 2 Update Java Sol 3 New cover March 2019 1 2 Slide rail update April 2019 1 3 Safety instruction update ...

Page 7: ...le for compliance could void your authority to operate the equipment Disclaimer AIC shall not be liable for technical or editorial errors or omissions contained herein The information provided is provided as is without warranty of any kind To the extent permitted by law neither AIC or its affiliates subcontractors or suppliers will be liable for incidental special or consequential damages includin...

Page 8: ...ully mount the equipment into the rack in such manner that it won t be hazardous due to uneven mechanical loading This equipment is to be installed for operation in an environment with maximum ambient temperature below 35 C The openings on the enclosure are for air convection to protect the equipment from overheating DO NOT COVER THE OPENINGS Never pour any liquid into ventilation openings This co...

Page 9: ...d and or damaged 6 The equipment has obvious signs of breakage 7 Please disconnect this equipment from the AC outlet before cleaning Do not use liquid or detergent for cleaning The use of a moisture sheet or cloth is recommended for cleaning Module and drive bays must not be empty They must have a dummy cover CAUTION The equipment intended for installation should be placed in Restricted Access Loc...

Page 10: ...de for assembling the main components of the JBOD Utmost caution for proceeding to set up the hardware is highly advised Do not endanger yourself by placing the device in an unstable environment The consequences for negligent actions may be extremely severe Chapter 3 Sub system Configuration Setup This chapter provides details about the supported features and unsupported configurations about your ...

Page 11: ... is found do not remove the components contact the dealer where the subsystem was purchased for further instructions Before continuing first unpack the subsystem and verify that the contents of the shipping carton are all there and in good condition 1 1 Box Content This product contains the components listed below Please confirm the number and the condition of the components before installation Sy...

Page 12: ...ancy Drive Bays 78 Cooling 8 x 6056 hot swap fans 1 x 4056 fan per expander module Power Supply 1600W 1 1 hot swap redundant 80 Platinum Power Entry Dual AC Inlet Expander Modules Dual expanders Optional Electrical and Environmental A C Input 200 240V AC Operating Environment Temperature 0ºC to 35ºC Relative humidity 20 to 80 Non operating Environment Temperature 20ºC to 60ºC Relative humidity 10 ...

Page 13: ... expander chip Broadcom SAS35x48 which is underscored for its high scalability and performance of supporting up to 12 Gb s this product enhances these features by integrating designs redundant fans and expansion to offer easy control and high performance for our custom ers Intelligent Enclosure Management Individual drive power management Easy maintenance and management Tool less drive trays Desig...

Page 14: ...wer Fail Temperature overheating and Fan Fault System Power Behavior Status Long Press System shut down Press Boot up Power LED Behavior Status On Blue Power Fail LED Behavior Status Failed Red Temperature Overheating LED Behavior Status Failed Red Fan Fault LED Behavior Status Failed Red System Alert Mute Switch Behavior Status Press Alert mute A B C D E F A B C D E F ...

Page 15: ...5 Chapter 1 Product Features J4078 01 User Manual BC BC 1 2 3 4 1 2 3 4 Rear Panel NOTE The power supply only supports 200V 240V AC input 4 x mini SAS HD 8 x 6056 fans 1600 W 1 1 redundant 80 Platinum ...

Page 16: ...Product Features J4078 01 User Manual Rear Expander Panel J4078 01 offers single dual expander s with 1 BMC port and 4 mini SAS HD ports per expander module BMC console port debug port BMC LAN port 4 x mini SAS HD ...

Page 17: ...7 Chapter 1 Product Features J4078 01 User Manual Major Components J4078 01 offers 3 5 x 78 HDD bays 12Gb s 6Gb s SAS if using dual expanders 12Gb s SAS and 6Gb s SATA if using single expander ...

Page 18: ...d Installing the Top Cover 2 1 1 Removing and Installing the First Top Cover Step 1 Push the release button on both sides of the top cover Step 2 Lift the cover from the chassis This information is provided for professional technicians only Chapter 2 Hardware Setup ...

Page 19: ...78 01 User Manual 2 1 2 Removing and Installing the Middle Top Cover Step 1 Push the release button on both sides of the top cover Step 2 Lift the cover from the chassis This information is provided for professional technicians only ...

Page 20: ...J4078 01 User Manual 2 1 3 Removing and Installing Rear Top Cover Step 1 Push the release button on both sides of the top cover Step 2 Lift the cover from the chassis This information is provided for professional technicians only ...

Page 21: ...he tray by placing it against each other Step 3 Insert the HDD into the tool less tray in the suggested order above Make certain to attach the side of the tray with the larger dimples to the HDD first and the side with the smaller dimples last for easier installation This information is provided for professional technicians only 2 2 Removing and Installing the Hard Disk Drive ...

Page 22: ...lation 2 2 2 Removing the 3 5 HDD from the Tray Pull the sides of the tray to remove the HDD Make certain to pull the tray with smaller dimples first away from the HDD and the larger dimples last for easier removal This information is provided for professional technicians only ...

Page 23: ... red circle Step 2 Match the dimples in dotted red circle on the HDD bracket and HDD with the tool less tray Image without HDD to demonstrate the location of dimple and screw Screw location in red circle Dimple location in the dotted red circle Step 3 Insert the bracket and HDD into the tool less tray Step 4 Secure the screws on the bracket to complete installation ...

Page 24: ...cage Make sure the drive tray is correctly secured in place when its front edge aligns with the bay edge Step 2 Push the tray lever until it reaches the end and clicks 2 2 4 2 Removing the HDD Tray Step 1 Press the release button on the tray lever Step 2 Pull upwards to remove the HDD tray from the enclosure This information is provided for professional technicians only ...

Page 25: ...ake sure the latch on the module is fully hooked onto the PSU housing 2 3 2 Removing the Power Supply Unit Step 1 Remove power cables connected to the power supply module Allow a minute for fan to spin down Step 2 Push the latch and hold the tray handle Step 3 Pull the power supply module gently until it slides out of the enclosure This information is provided for professional technicians only ...

Page 26: ... Installing the Fan Align the fan module with the opening in the enclosure and insert the module into the JBOD 2 4 2 Removing the Fan Step 1 Loosen the thumb screws x 2 pcs on the fan module Step 2 Pull the fan module from the enclosure This information is provided for professional technicians only ...

Page 27: ...r module with the opening in front of the enclosure and insert it into the enclosure Step 2 Close the lever and secure the retaining screw 2 5 2 Removing the Expander Loosen the screw to remove This information is provided for professional technicians only 2 5 Removing and Installing the Expander Module ...

Page 28: ...ition the brackets x 4 on the top of the HDD backplane module and secure the screws x 8 pcs 1 bracket with 2 screws each Step 3 Repeat step 1 and step 2 to install the second backplane 2 6 2 Removing the HDD Backplane Step 1 Remove the HDD disk trays from the enclosure Step 2 Remove the top brackets x 4 from the chassis by removing the screws x 8 pcs 1 bracket with 2 screws each Step 3 Remove the ...

Page 29: ...19 Chapter 2 Hardware Setup J4078 01 User Manual Bracket and HDD backplane removal Bracket and second HDD backplane removal This information is provided for professional technicians only ...

Page 30: ... handle with the locks on the chassis Step 2 Pull the handle upward to lock the handle onto the chassis 2 7 2 Removing the Rear Handle Step 1 Push the handle downward to dismatle the lock from the handle Step 2 Remove the handle from the chassis This information is provided for professional technicians only Aligning the handle with the chassis Securing the handle ...

Page 31: ...nsure that the latch on the rail is hooked onto the rack Align and attach the rear rail braket to the rack by pushing the latch outward Ensure the latch is hooked onto the rack Ensure that the latch on the rail is hooked onto the rack Secure the rail bracket with a washer and screw on both sides of the rail bracket Repeat to to install the other side of the rack Screw_M5x10L Washer_ 5 1 ...

Page 32: ... the inner and middle rail to fully locked position Position the chassis vertically into the rail Ensure the standoffs on the chassis slide into the v slots on the rail bracket Secure the chassis to the rail with screws Push the release tab on the inner rail and push the chassis into the frame ...

Page 33: ...SAS drive 2 SATA drive with an interposer which provides SATA to SAS conversion Locating a drive via any HBA utility is not supported Users should send standard SES command to the enclosure 4U78swapHub to locate a drive 3 1 2 Unsupported Feature 1 Enclosure logical identifier can be changed 2 Locating a drive via any HBA utility Users should send standard SES command to locate a drive 3 The manage...

Page 34: ...nfiguration Settings J4078 01 User Manual 1 Push the key it will show the IPMI serial interface Type command for login the interface sys pwd u admin admin It will response OK 4 1 Login Chapter 4 BMC Configuration Settings ...

Page 35: ... 00 00 Find LAN IP 30 00 02 01 03 00 00 Find submask 30 00 02 01 06 00 00 Find gateway 30 00 02 01 0C 00 00 Find LAN static IP DHCP 01 is static IP and 02 is DHCP The red box represents hexadecimal digits According to the left figure the IP is 16 12 0 192 16 10 8 168 16 5 8 88 16 6 11 107 Therefore the IP is 192 168 88 107 ...

Page 36: ...01 01 03 C0 A8 00 0A Set submask 30 00 01 01 06 FF FF FF 00 Set gateway 30 00 01 01 0C C0 A8 00 01 The Green digits is the returned code The green digits in the red box is completion code 00 represents the confirmed code The blue digits are can be configured to any value If you want to change the IP address you must set the LAN status to static ...

Page 37: ... port Set the local host IP to 192 168 11 xx segment 5 Open the web browser and enter default IP http 192 168 11 11 When the login window appears set the user name and password to admin 6 Click Log In to continue Type the default account and password Account admin Password admin ...

Page 38: ...anual 4 2 Sensor s Location for Fan Temperature EXP expander chip 46 47 48 49 50 46 47 48 49 50 55 56 46 47 48 49 50 U80 U6 Front U92 U11 U80 U6 UP fan 7 fan 5 fan 3 fan 1 Down fan 8 fan 6 fan 4 fan 2 Q21 Q20 Sec EXP Up Pri EXP Down Sec EXP Up Pri EXP Down ...

Page 39: ...panal Step 2 Log into the BMC interface Please refer to 4 1 Login Step 3 Initiate Java SOL Use one of the methods below to configure the expander setting 4 3 1 Java SOL There are two methods to initiate Java Sol Method 1 1 Select an expander under Select expander and click Java Sol 2 Download jsol jnlp file and proceed to execute the program ...

Page 40: ...0 Chapter 4 BMC Configuration Settings J4078 01 User Manual 3 Check the warning message option and execute it If JAVA blocks this action please set the IP in order to access web site in the JAVA setting ...

Page 41: ...31 Chapter 4 BMC Configuration Settings J4078 01 User Manual 4 Input the BMC IP account password and set the baud rate to 38 4 5 Now you can use the expander smart console via BMC SOL 4U78swap Hub ...

Page 42: ...32 Chapter 4 BMC Configuration Settings J4078 01 User Manual Method 2 1 In addition you can use ipmitool to start SOL function ipmitool I lanplus H BMC IP U admin P admin sol activate ...

Page 43: ...other expander you do not need to close SOL Use the command below to switch your expander SET EXANDER NetFN 36 Command Code 54h Message Byte Data Field Request 1 Expander select 01h Hub 02h Edge_0 03h Edge_1 04h Edge_2 Response 1 Completion Code 00h Success CCh Invalid value data ipmitool I lanplus H BMC IP U admin P admin raw 0x36 0x54 0x1 ...

Page 44: ...the first port and another drive accessed only by the second port The configuration for the example is A PHY8 PHY11 for the first wide port of HUB B PHY4 PHY7 for the second wide port of HUB C PHY20 PHY35 for drives on EDGE Step 1 Read the current group for PHY4 of HUB cmd phyzone 4 Phy 4 for Zone Group 1 Step 2 Assign the second port PHY4 PHY7 for Group9 cmd phyzone 4 9 cmd phyzone 5 9 cmd phyzon...

Page 45: ...000272BF B Set the enclosure address with 0x500605B0000272BF The new setting will take effect after reset cmd enclosure_addr 500605B0000272BF cmd reset 4 3 2 4 How to configure standby timer for all disk drives EDGE only This feature is applicable for SAS SATA drives Standby timer is in units of minutes Setting standby timer with 0 minute disables this feature A Get current standby timer cmd stand...

Page 46: ...cker cmd check_wide_port Checking wide port is OFF B Enable checking wide port The new setting will take effect after reset cmd check_wide_port on cmd reset C Disable checking wide port The new setting will take effect after reset cmd check_wide_port off cmd reset 4 3 2 6 How to power off on all disk drives automatically This feature is applicable for SAS SATA drives If there is no connection with...

Page 47: ...sable the EDFB cmd edfb off 4 3 2 8 How to configure power setting HUB only This feature is for restoring on AC power loss Three supported options are keep off keep on and keep last state The default setting is keep off A Get the current power setting cmd power_setting Power setting keep off B Set keep off cmd power_setting keep_off C Set keep on cmd power_setting keep_on D Set keep last state cmd...

Page 48: ... zone count Power on the 4U78swap and then insert the SAS cable Three zone configurations supported are one zone two zones and four zones The default configuration is one zone of which T10 zoning configuration is disabled T10 zoning configuration of the other configurations two zones and four zones is enabled All COM ports for HUB and EDGE should be applied with the same configuration A Get curren...

Page 49: ...pter 4 BMC Configuration Settings J4078 01 User Manual EDGE Zone 1 2 Slot 1 39 40 78 C 3 When Zone Count 4 T10 zoning is enabled HUB Zone 1 2 3 4 Wideport 1 2 3 4 EDGE Zone 1 2 3 4 Slot 1 20 21 40 41 60 61 78 ...

Page 50: ...FIGURE BELOW Expander rear panel Group 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 Top View UP fan 1 fan 3 fan 5 fan 7 Down fan 2 fan 4 fan 6 fan 8 Sec EXP Up Pri EXP Down Front Front ...

Page 51: ...oup 2 SEE FIGURE BELOW Group 1 Group 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 Top View UP fan 1 fan 3 fan 5 fan 7 Down fan 2 fan 4 fan 6 fan 8 Sec EXP Up Pri EXP Down Front Front ...

Page 52: ...p 2 Port 3 is in zone group 3 Port 4 is at zone group 4 SEE FIGURE BELOW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 Top View UP fan 1 fan 3 fan 5 fan 7 Down fan 2 fan 4 fan 6 fan 8 Sec EXP Up Pri EXP Down Front Front ...

Page 53: ...ne_port 1 Wideport 01 for Zone Group 01 B Set wideport 1 as Zone Group 8 cmd zone_port 1 8 Succeeded to set zone group for the phy 4 3 2 11 How to configure zoning of the disk slot EDGE only After enabling T10 zoning five predefined groups are Group1 Group8 Group9 Group10 and Group11 A Get current zoning of Disk Slot 10 cmd zone_slot 10 Slot 10 for Zone Group 1 B Set Disk Slot 10 as Zone Group 8 c...

Page 54: ...For detailed information please visit http www t10 org If you are a member of the T10 working group the Standard which controlled by T10 technical committee could be found at http www t10 org cgi bin ac pl t f f ses2r19a pdf 4 3 3 1 SES Pages 00h List of supported diagnostic pages 01h SES configuration 02h SES enclosure control enclosure status 04h SES String In 05h SES Threshold Out In 07h SES el...

Page 55: ...3 PSU Module2 STATUS_WORD 4 5 14 Reserved 0xFF SES Threshold Out In It includes only Temperature Sensor and Voltage Sensor elements Threshold control element format BYTE BIT 7 6 5 4 3 2 1 0 0 REQUESTED HIGH CRITICAL THRESHOLD 1 REQUESTED HIGH WARNING THRESHOLD 2 REQUESTED LOW WARNING THRESHOLD 3 REQUESTED LOW CRITICAL THRESHOLD Threshold status element format BYTE BIT 7 6 5 4 3 2 1 0 0 HIGH CRITIC...

Page 56: ...0 then canister number is restored to default 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 8 spaces in ASCII Canister Number control format BYTE BIT 7 6 5 4 3 2 1 0 0 N Canister Number If no canister number is found return Status 1 failed only else return Status 0 success followed by canister number Canister Number status format BYTE BIT 7 6 5 4 3 2 1 0 0 Status 0 success 1 failed 1 N if success Canist...

Page 57: ... Element Control Functions for details B Power Supply Status Element BYTE BIT 7 6 5 4 3 2 1 0 0 COMMON STATUS Reserved PRDFAIL DISABLE SWAP ELEMENT STATUS CODE 1 IDENT Reserved 2 Reserved DC OVER VOLTAGE DC UNDER VOLTAGE DC OVER CURRENT Reserved 3 HOT SWAP FAIL RQSTED ON OFF OVERTMP FAIL TEMP WARN AC FAIL DC FAIL Field Value ELEMENT STATUS CODE OK No failure or warning conditions detected CRITICAL...

Page 58: ...ontrol Functions for details B Cooling Status Element BYTE BIT 7 6 5 4 3 2 1 0 0 COMMON STATUS Reserved PRDFAIL DISABLE SWAP ELEMENT STATUS CODE 1 IDENT Reserved ACTUAL FAN SPEED MSB 2 ACTUAL FAN SPEED LSB 3 HOT SWAP FAIL RQST ON OFF Reserved ACTUAL SPEED CODE Field Value ELEMENT STATUS CODE OK Actual fan speed 0 CRITICAL The fan RPM can t be detected or equal to 0 IDENT Applicable only for Coolin...

Page 59: ...ODE 1 IDENT FAIL Reserved 2 TEMPERATURE 3 Reserved OT FAILURE OT WARNING UT FAILURE UT WARNING Field Value ELEMENT STATUS CODE OK Everything is Ok NON CRITICAL If either warning limit is exceeded CRITICAL If either failure limit is exceeded FAIL A warning or failure condition is detected TEMPERATURE Temperature reading OT FAILURE Temperature has exceeded the failure high threshold value OT WARNING...

Page 60: ...ctions for details REQUEST FAILURE Please refer to section SES Element Control Functions for details REQUEST WARNING Please refer to section SES Element Control Functions for details B Enclosure Status Element BYTE BIT 7 6 5 4 3 2 1 0 0 COMMON STATUS Reserved PRDFAIL DISABLE SWAP ELEMENT STATUS CODE 1 IDENT Reserved 2 TIME UNTIL POWER CYCLE FAILURE INDICATION WARNING INDICATION 3 REQUEST POWER OFF...

Page 61: ... power cycle is scheduled or ii It is scheduled to be kept off for 10 seconds 1 60 Power is scheduled to be kept off for the indicated number of minutes 63 Power is scheduled to be kept off until manually restored FAILURE REQUESTED Set by the REQUEST FAILURE on Enclosure Control Element WARNING REQUESTED Set by the REQUEST WARNING on Enclosure Control Element ...

Page 62: ...US CODE 1 IDENT FAIL Reserved WARN OVER WARN UNDER CRIT OVER CRIT UNDER 2 VOLTAGE 3 Field Value ELEMENT STATUS CODE OK Everything is Ok NON CRITICAL If either warning limit is exceeded CRITICAL If either failure limit is exceeded FAIL A warning or failure condition is detected WARN OVER Voltage has exceeded the warning high threshold value WARN UNDER Voltage is below the warning low threshold valu...

Page 63: ... RQST IN CRIT ARRAY Please refer to section SES Element Control Functions for details RQST IN FAILED ARRAY Please refer to section SES Element Control Functions for details RQST REBUILD REMAP Please refer to section SES Element Control Functions for details RQST R R ABORT Please refer to section SES Element Control Functions for details RQST ACTIVE Please refer to section SES Element Control Funct...

Page 64: ... Control Element RSVD DEVICE Set by the RQST RSVD DEVICE on Array Device Control Element HOT SPARE Set by the RQST HOT SPARE on Array Device Control Element CONS CHK Set by the RQST CONS CHECK on Array Device Control Element IN CRIT ARRAY Set by the RQST IN CRIT ARRAY on Array Device Control Element IN FAILED ARRAY Set by the RQST IN FAILED ARRAY on Array Device Control Element REBUILD REMAP Set b...

Page 65: ... command When the RQST IDENT bit is set the blue LED overwrites its default behavior with a slow blink while the red LED is off The blue LED is set Activity for not overwriting its default behavior The behavior Fast Blink is LED is blinking at 2Hz frequency The behavior Slow Blink is LED is blinking at 0 5Hz frequency The behavior ON OFF is LED is solid ON OFF without blinking Slot Control Bit Blu...

Page 66: ...trol element in the SES specification Set the bit to turn off a slot power and vice versa We use the software package sg3_utils on Linux for example and have a SAS HBA and a cable to connect your host with the expander A Show the device for AIC Expander Controller canister sg_map i dev sg2 AIC 12G 4U78swapEdge 0c31 B Get the current state of a slot power The Device off 0 means the slot power is on...

Page 67: ...pply is defined in the bit5 byte3 of the Power Supply control element in the SES specification Clear the bit on Power Supply Element PowerSupply00 or PowerSupply01 to power off the entire enclosure We use the software package sg3_utils on Linux for example and have a SAS HBA and a cable to connect your host with the expander A Show the device for AIC Expander Controller canister sg_map i dev sg2 A...

Page 68: ...fication Set POWER CYCLE REQUEST as 01b to begin a power cycle in minutes set by POWER CYCLE DELAY 1 60 minutes 0 for beginning power cycle immediately and keep off for minutes set by POWER OFF DURATION set 1 60 minutes 0 for 10 seconds and 63 for keeping off A request to begin a power cycle while a previous request is still active should override the previous request Set POWER CYCLE REQUEST as 10...

Page 69: ...byte3 and bit0 byte3 of the Enclosure control element in the SES specification Setting either bit can enable the enclosure alarm Clearing both bits disables the enclosure alarm We use the software package sg3_utils on Linux for example and have a SAS HBA and a cable to connect your host with the expander A Show the device for AIC Expander Controller canister sg_map i dev sg2 AIC 12G 4U78swapHub 0c...

Page 70: ...isable the smart fan function before changing PWM or fan speed Only the first Cooling element of each type HUB fans and System fans supports this feature We use the software package sg3_utils on Linux for example and have a SAS HBA and a cable to connect your host with the expander A Show the device for AIC Expander Controller canister sg_map i dev sg2 AIC 12G 4U78swapHub 0c30 B Set RQST IDENT of ...

Page 71: ...61 Chapter 4 BMC Configuration Settings J4078 01 User Manual REQUESTED SPEED CODE PWM 7 100 6 90 5 80 4 70 3 60 2 50 1 40 0 Leave at current speed ...

Page 72: ...behind the hub so please follow the steps below to update firmware and MFG of the Edge0 via inband SAS The same steps can be applied to all the other edges We use the software package sg3_utils and LSI utility g3Xflash on Linux for example and have a SAS HBA and a cable to connect your host with the expander A Show the device for AIC Expander Controller sg_map i dev sg2 AIC 12G 4U78swapHub 0c30 B ...

Page 73: ...3 in MFG filename mode 0x2 offset 0 dev sg2 H Get SAS address of Edge0 The SAS address 50015B20 9000EBBF is used for the Edge0 g3Xflash i get avail I Reset the Edge0 to activate its new firmware MFG g3Xflash i 50015b209000ebbf reset exp J Get the current firmware version of the Edge0 for confirmation g3Xflash i 50015b209000ebbf get ver K Set Reserved5 of Disk001 to make the Edge0 invisible sg_ses ...

Page 74: ...er connection NetFN 36 Command Code 53h Message Byte Data Field Request 1 Expander select 01h Hub 02h Edge 0 03h Edge 1 04h Edge 2 Response 1 Completion Code 00h Success 2 Expander select value ipmitool I lanplus H BMC IP U admin P admin raw 0x36 0x54 0x1 3 Read expander Edge 0 counter value Execute ipmi command to configure BMC SOL to Edge 0 ipmitool I lanplus H BMC_IP U admin P admin raw 0x36 0x...

Page 75: ...65 Chapter 4 BMC Configuration Settings J4078 01 User Manual 4 Type in counters to execute counters command ...

Page 76: ...BMC Configuration Settings J4078 01 User Manual 5 To read the the expander Edge 1 counter value 1 execute the ipmi command to configure BMC SOL to Edge 1 ipmitool I lanplus H BMC_IP U admin P admin raw 0x36 0x54 0x3 ...

Page 77: ...67 Chapter 4 BMC Configuration Settings J4078 01 User Manual 6 Type in counters to execute counters command ...

Page 78: ... reload the console preview Sensor Monitoring It lists all available sensors on the device with information such as status name reading and status icon as well as a link to that sensor s page There are 3 possible states for a Sensor Green dot denotes a Normal state Yellow exclamation mark denotes a Warning state Red x denotes a Critical state The magnifying glass allows access to the Sensor detail...

Page 79: ...ng Chassis information fields Area Format Version Chassis Type Chassis Part Number Chassis Serial Number Chassis Extra Board Information It displays the following Board information fields Area Format Version Language Manufacture Date Time Board Manufactu Board Product Name Board Serial Number Board Part Number FRU File ID Board Extra Product Information It displays the following Product informatio...

Page 80: ...r Off button to control HDD power ACTIONS Power On Select a HDD to turn it power on Power off Select a HDD to turn it power off Icon status Green The HDD is inserted into this slot and the power is on Red The HDD is inserted into this slot but there is an system error Gray The HDD is not inserted into the slot and the power is off Orange This slot is rebuilding ...

Page 81: ...l representation of all associated events Double click on a record to toggle ON OFF the live widget for that particular sensor You can filter the list to view particular sensors only using the drop down listbox NOTE N A represents Not Applicable Live Widget Turn On or Off the live widget for this sensor This widget gives a dynamic representation of the readings for the sensor View this Event Log C...

Page 82: ...the device BMC Timezone Check this option to display the event log entries logged with the BMC Timezone value Client Timezone Check this option to display the event log entries logged with the Client user s Timezone value UTC Offset Displays the current UTC Offset value based on which event Time Stamps will be updated Navigational arrows can be used to selectively access different pages of the Eve...

Page 83: ...evice if Auto is selected If the Host setting is chosen as Manual then specify the hostname of the device Register BMC Choose the BMC s network port to register with the DNS settings Check the option Register BMC to register with the DNS settings Choose the option Direct Dynamic DNS to register with direct dynamic DNS or choose DHCP Client FQDN to register through a DHCP server Domain Name Configu...

Page 84: ...nd 1 IPv6 DNS server If the IP Priority is IPv6 it will have 2 IPv6 DNS servers and 1 IPv4 DNS server NOTE This is not applicable for Manual configuration DNS Server 1 2 3 Specify the DNS Domain Name System server address to be configured for the BMC An IPv4 Address is made of 4 numbers separated by dots as in xxx xxx xxx xxx Each number ranges from 0 to 255 The first number must not be 0 DNS Serv...

Page 85: ...s of the selected interface read only IPv4 Configuration It lists the IPv4 configuration settings Obtain an IP address automatically Enable Use DHCP to dynamically configure the IPv4 address using Dynamic Host Configuration Protocol DHCP IPv4 Address Subnet Mask Default Gateway If DHCP is disabled specify a static IPv4 address Subnet Mask and Default Gateway to be configured for the selected inter...

Page 86: ...dress using Dynamic Host Configuration Protocol DHCP IPv6 Address Specify a static IPv6 address to be configured for the selected interface Subnet Prefix length Specify the subnet prefix length for the IPv6 settings Value ranges from 0 to 128 Default Gateway Specify the v6 default gateway for IPv6 settings Save Click Save to save any changes made You will be prompted to log out of the current UI s...

Page 87: ... are to be configured Auto Negotiation This option is enabled to allow the device to perform automatic configuration to achieve the best possible mode of operation speed and duplex over a link Link Speed Link speed will list all the supported capabilities of the network interface It can be 10 100 1000 Mbps Duplex Mode Select any one of the following Duplex Modes Half Duplex Full Duplex Save Click ...

Page 88: ...device NOTE As a year 2038 problem exists the acceptable date range is from 01 01 2005 to 01 18 2038 NTP Server Specify the NTP Server for the device Check the Automatically synchronize option to configure the NTP Server The NTP Server will support the following IP Address Both IPv4 and IPv6 format FQDN Fully qualified domain name format UTC Offset UTC Offset list contains the UTC offset values fo...

Page 89: ...l Automatically synchronize Check this option to automatically synchronize Date and Time with the NTP Server Refresh Click Refresh to reload the current date time settings Save Click Save to save any changes made Reset Click Reset to reset the modified changes ...

Page 90: ... and available slots You can modify or add new event filter entries here A maximum of 40 slots are available and include the default of 15 event filter configurations Alert Policy Click the Alert policy tab to show configured Alert policies and available slots You can modify or add new alert policy entries here A maximum of 60 slots are available LAN Destination Click the LAN Destination tab to sh...

Page 91: ...rt can be enabled under Configuration SMTP Add Select a free slot and click Add to add a new entry to the device Alternatively double click on a free slot Modify Select a configured slot and click Modify to modify that entry Alternatively double click on the configured slot Delete Select the desired configured slot to be deleted and click Delete ...

Page 92: ...Enter the Machine Name of the SMTP Server Machine Name is a string of maximum 15 alpha numeric characters Space special characters are not allowed Primary SMTP Server It lists the Primary SMTP Server configuration SMTP Support Check this option to enable SMTP support for the BMC Server Address Enter the IP address of the SMTP Server It is a mandatory field An IP Address is made of 4 numbers separa...

Page 93: ...Username Enter the username to access SMTP Accounts The User Name can be 4 to 64 alpha numeric characters It must start with an alphabet Special characters comma colon semicolon space and backslash are not allowed Password Enter the password for the SMTP User Account Passwords must be at least 4 characters long Space is not allowed NOTE This field will not allow more than 64 characters Secondary S...

Page 94: ...er Manual 4 4 5 7 Schedule Power ON OFF This page displays the device s current date time It can be used to configure dates within a week or specific a date to power on off the device If you want to change the device date time please go to the NTP page ...

Page 95: ...nable schedule Check this option for enable disable the schedule Action Check a action to do power on off for the device Set days for action Setting dates within a week to do power on off for the device Date Specify a date for the device Time Specify a time for the device ...

Page 96: ...dified as a security measure To view the page you must have Operator privileges To modify or add a user You must have Administrator privileges NOTE Free slots are denoted by in all columns for the slot Add User Select a free slot and click Add User to add a new user to the device Alternatively double click on a free slot to add a user Modify User Select a configured slot and click Modify User to m...

Page 97: ...w or perform any host power cycle operations Power Off Storage Select this option to immediately power off the storage Power On Storage Select this option to power on the storage Power Cycle Storage Select this option to first power off and then reboot the system cold boot Perform Action Click Perform Action to perform the selected option ...

Page 98: ...ng in this page Set zone value You can set a zone count value and click the SET button The BMC will be configured on all of the hub and edge expander Refresh status Select an expander location and click refresh for get the zone count status Zone Count This will show the current zone count value Below command is for ipmitool use ...

Page 99: ...ompletion Code 00h Success 2 zone count value ipmitool I lanplus H BMC IP U admin P admin raw 0x36 0x52 0x1 SET ZONE COUNT NetFN 36 Command Code 53h Message Byte Data Field Request 1 Expander select 00h Set all expander 01h Hub 02h Edge_0 03h Edge_1 04h Edge_2 2 zone count value Response 1 Completion Code 00h Success CCh Invalid value data ipmitool I lanplus H BMC IP U admin P admin raw 0x36 0x53 ...

Page 100: ... or later version Linux Redhat 6 4 If you want to update a new version firmware for BMC when finished all the update process please clear the web browser cookies 4 5 2 Web update 1 Check if the BMC IP is valid 2 Open a browser and type in the BMC IP It will show the BMC web UI Type in the default account or use the administrator privileged account Username admin Password admin ...

Page 101: ...91 Chapter 4 BMC Configuration Settings J4078 01 User Manual 3 This is login main page 4 Click the Firmware Update and it will pop a drop down menu Click Firmware Update ...

Page 102: ...78 01 User Manual 5 This page shows the update warning If you want to update the BMC firmware click the Enter Update Mode button 6 Wait a few minutes and a window will pop up Click Select file to upload the firmware file that you want to update ...

Page 103: ... Settings J4078 01 User Manual 7 Wait a few minutes and the window that checks the update section will pop up Check the Check this option to do all full firmware flash option 8 Click OK and the firmware will start the update process ...

Page 104: ...n the update process it will take 3 5 minutes Caution Please do not close this webpage Closing the web page may cause the firmware to crash 10 When Device has been reset window appears it means the firmware update is successful Wait 90 seconds for the BMC to restart ...

Page 105: ...ess of the server where the firmware image is stored IP Address made of 4 numbers separated by dots as in xxx xxx xxx xxx Each number ranges from 0 to 255 First number must not be 0 Source Path Full Source path including image filename to its location on server Retry Count Number of times to be retried in case a transfer failure occurs Retry count ranges from 0 to 255 Save Click Save to save the c...

Page 106: ... Configuration Settings J4078 01 User Manual 4 6 Expander Firmware MFG Update 1 Click Firmware Update Expander Firmware Update in your BMC menu bar 2 Under Select the expander choose an expander and click Start update ...

Page 107: ...97 Chapter 4 BMC Configuration Settings J4078 01 User Manual 3 Click Choose File 4 Select and click Open ...

Page 108: ...98 Chapter 4 BMC Configuration Settings J4078 01 User Manual 5 Click Upload 6 Click Proceed ...

Page 109: ...99 Chapter 4 BMC Configuration Settings J4078 01 User Manual 7 Wait a few seconds 8 Click Choose File ...

Page 110: ...100 Chapter 4 BMC Configuration Settings J4078 01 User Manual 9 Choose bin and click Upload 10 Click Proceed ...

Page 111: ...101 Chapter 4 BMC Configuration Settings J4078 01 User Manual 11 Update complete 12 To select another expander please refer to steps 2 to 11 ...

Page 112: ...u aicipc com tw North California United States Address 48531 Warm Springs Boulvard Suite 404 Fremont CA 94539 United States Tel 1 510 573 6730 Fax 1 510 573 6729 Sales Email sales aicipc com Support Email support aicipc com South California United States Address 21808 Garcia Lane City of Industry CA 91789 United States Toll free 7 4997019998 Tel 1 909 895 8989 Fax 1 909 895 8989 157 Sales Email sa...

Reviews: