42
SPARC Enterprise T5440 Server Product Notes • December 2010
Workaround: None. Connect the LAN cable to the NET-MGT port of ILOM and then
set the network configuration.
After the Power Cord Removal/Insert, an Error
Message May Appear during the POST
After you remove/insert the power cord and while POST is running, the
"
/SYS/XXXXX prom is unreadable or corrupted
" message may appear and
stop at
ok
prompt.
Message example:
->
set /SP/network/ commitpending=true
set: Unable to get network management property
->
->
show /SP/network/ -d properties
/SP/network
Properties:
commitpending = (Cannot show property)
dhcp_server_ip = none
ipaddress = (none)
ipdiscovery = (none)
ipgateway = (none)
ipnetmask = (none)
macaddress = (none)
pendingipaddress = 192.9.200.33
pendingipdiscovery = static
pendingipgateway = (none)
pendingipnetmask = 255.255.255.0
state = disabled
Chassis | major: Host has been powered on
0:0:0>
0:0:0>SPARC-Enterprise[TM] T5440 POST 4.30.6 2009/12/01 13:08
/export/delivery/delivery/4.30/4.30.6/post4.30.6-micro/Niagara/huron/inte
grated (root)
0:0:0>Copyright 2009 Sun Microsystems, Inc. All rights reserved
0:0:0>POST enabling CMP 0 threads: ffffffff.ffffffff
0:0:0>VBSC mode is: 00000000.00000001
0:0:0>VBSC level is: 00000000.00000001
0:0:0>VBSC selecting Normal mode, MAX Testing.
0:0:0>VBSC setting verbosity level 2
0:0:0>Basic Memory Tests....Done
0:0:0>Test Memory....Done
0:0:0>Setup POST Mailbox ....Done
Summary of Contents for SPARC Enterprise T5440 Server
Page 4: ......
Page 18: ...8 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 38: ...28 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 58: ...48 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 66: ...56 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 92: ...82 SPARC Enterprise T5440 Server Product Notes December 2010 ...