Chapter 3
Known Issues
37
6726663
In ILOM mode, or through access to the ILOM
Web, it may be possible to change the system
time when the system is powered on.
In ILOM mode, be sure not to change the
properties displayed below at power on so as
not to change the system time directly or enable
NTP services.
->
show /SP/clock
/SP/clock
Targets:
Properties:
datetime = Wed Dec 3 06:22:48 2008
usentpserver = disabled
Commands:
cd
set
show
-
>
6823561
In the back up and restore functions of ILOM
settings, you cannot set "https" to the protocol
for data transfer (
transfer_method
property
).
Example:
->
set dump_uri=
https://ipaddres/directory/filename
set: Unable to transfer image,
please check URI
None.
Use other protocols (tftp, ftp, sftp, scp, http).
6830397
In ILOM3.0, you cannot set "
service
" to the
/HOST/diag mode
property or the
diag_mode
property of the ALOM CMT compatible shell. If
you set, it is displayed as "
unknown
."
None.
The following settings offer the POST diagnosis
in a mode equivalent to the "
service
."
/HOST/diag mode = normal
/HOST diag level = max
/HOST verbosity = max
6835854
6779753
In case that the NET-MGT port of ILOM has not
been connected with the LAN cable and the
network gateway is not set, the ILOM network
configuration cannot be set.
For the output example, see
Network Configuration Cannot Be Set (CR
6835854, 6779753)” on page 41
None.
Connect the LAN cable to the NET-MGT port of
ILOM and then set the network configuration.
TABLE 3-4
ILOM Issues
(Continued)
CR ID
Description
Workaround
Summary of Contents for SPARC Enterprise T5440 Server
Page 4: ......
Page 18: ...8 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 38: ...28 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 58: ...48 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 66: ...56 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 92: ...82 SPARC Enterprise T5440 Server Product Notes December 2010 ...