![background image](http://html.mh-extra.com/html/fujitsu/sparc-enterprise-t5440-server/sparc-enterprise-t5440-server_user-manual_121367077.webp)
Appendix A
Fixed Issues
67
6919764
In System Firmware 7.2.7.b, after the power-on
of a system mounted with the 4Gbps Fibre
Channel card manufactured by Fujitsu, the
message "
F20CARD prom is unreadable or
corrupted
" may appear in the ILOM event log
and the Service Required LED may turn on.
Solaris OS completes the startup normally, and
the fibre channel card is normally recognized on
Solaris OS.
For details, see
.
Note - Fixed in System Firmware 7.2.8 or later.
After you insert the power cord, or after the
ILOM reset complete, wait for about 180 seconds
and then power on the system.
6913105
6908024
When connected to OS console via ILOM, input
or display to console may not be enabled. And at
this time, output from OS to console may fail.
Note - Fixed in System Firmware 7.2.8 or later.
After the system stop, disconnect the power cord
and then reconnect the power cord.
6942238
When you mount a link card connected to PCI
box and start the system, the slot number is
falsely displayed in the LEDs and FRU Status of
the
prtdiag -v
command output.
For details, see
Connected to PCI Box Is Falsely Displayed (CR
6942238)” on page 73
.
Note - Fixed in System Firmware 7.2.10 or later.
None.
This can be safely ignored. To check the fibre
channel card mount, use IO Devices of the
prtdiag
command of Solaris OS.
Connected to PCI Box Is Falsely Displayed (CR
6942238)” on page 73
6948680
When you change the system diagnostics
settings (
/HOST/diag
) from "Remote Control"->
"Diagnostics" tab in the ILOM Web interface, the
value of "
Trigger
" fails to be set with a pop-up
message "Error:Invalid property value," if the
following value is singly selected for the
"
Trigger
".
•
Power On
•
User Reset
Note - Fixed in System Firmware 7.2.10 or later.
None.
Use the
set /HOST/diag trigger=
(value)
command from the ILOM CLI
interface.
TABLE A-3
Fixed ILOM Issues
(Continued)
CR ID
Description
Workaround
Summary of Contents for SPARC Enterprise T5440 Server
Page 4: ......
Page 18: ...8 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 38: ...28 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 58: ...48 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 66: ...56 SPARC Enterprise T5440 Server Product Notes December 2010 ...
Page 92: ...82 SPARC Enterprise T5440 Server Product Notes December 2010 ...