SPARC Enterprise T5140 and T5240 Servers Product Notes • November 2012
After a Faulty PSU Replaced on the T5140 Server, the Fault
Indication May Not Be Cleared (CR 6967929)
This issue is resolved by updating the system firmware to 7.2.10 or later.
After a PSU failure occurred on the T5140 server, even though you replaced the faulty PSU,
the fault indication may not be cleared or the Service Required LED and the [REARPS] LED
may remain on. Also, in the result of the
showenvironment
command of ALOM CMT
compatible shell,
/SYS/PS_FAULT
may remain
ON
.
6902381
When you powered on the server, all LEDs or all
LEDs on the right side on the front panel may light
up. When using System Firmware 7.2.2.e or later, the
ILOM status check command (the
showenvironment
command) also displays the
status of relevant LED being ON; however, this event
itself is an issue absolutely limited to the LED
display and does not have an effect on the system.
Note - Fixed in System Firmware 7.2.10 or later.
None.
When this event occurred, perform the ILOM reset
operation. If not recovered, shut down the system and
then remove and insert the power cord.
ILOM reset operation example:
Log in to ILOM and execute the following command.
[Using ILOM command mode]
->
reset /SP
Are you sure you want to reset /SP
(y/n)?
y
[Using ALOM CMT compatible shell]
sc>
resetsc
Are you sure you want to reset the
SC [y/n]?
y
6847031
On the server with a CPU frequency of 1.6 GHz and
a built-in hard disk device consisting of 16 disks, the
power input sensor may have a displayed lower
threshold value (
/SYS/PSX/V_IN_MAIN
lower_noncritical_threshold
) of
0.000
Volts
or
N/A
.
The displayed value during normal operation is
163.200 Volts
.
Therefore, the power input sensor cannot detect
critical input power problems in the server.
For examples, see
“On the Server with a Specific
Note - Fixed in System Firmware 7.2.10 or later.
None.
TABLE A-6
Issues Fixed in System Firmware 7.2.10 or Later
(Continued)
CR ID
Description
Workaround
Summary of Contents for SPARC Enterprise T5140
Page 4: ......
Page 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...