Appendix A
Fixed Issues
99
On the DC Input Power Model, the "Environmental Status"
and Some Part of the "FRU Status" Information Is Not
Displayed (CR 6853843)
This issue is resolved by updating the system firmware to 7.2.7.b or later.
On the DC input power model of SPARC Enterprise T5140 Server, when you execute the
prtdiag
command of Solaris OS, the "Environmental Status" and some part of the "FRU
Status" information is not displayed.
Incomplete Data Output Example:
Workaround:
None. From ILOM, check the component information and the status of fan,
temperature, power sensor and so on.
In the Output from the
prtdiag
Command, Warnings May
Be Displayed (CR 6821325)
This issue is resolved by updating the system firmware to 7.2.7.b or later.
In the output from the
prtdiag
command, warnings may be displayed for input voltage
sensors(V_IN_MAIN) on power supply units.
============================ Environmental Status ============================
<-- No data output.
============================ FRU Status ============================
Location Name Status
------------------------------------------------------
SYS MB enabled
SYS HDD0 enabled
SYS HDD1 enabled
<-- Part of data is not on display.
Voltage sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/MB/CMP0/MR0
V_VMEM
ok
SYS/MB/CMP0/MR0
V_+1V5_VDD
ok
SYS/MB/CMP1/MR1
V_VMEM ok
SYS/MB/CMP1/MR1
V_+1V5_VDD
ok
SYS/MB
V_+3V3_STBY
ok
SYS/MB
V_+3V3_MAIN
ok
SYS/MB
V_+12V0_MAIN
ok
SYS/MB
V_VDDIO ok
Summary of Contents for SPARC Enterprise T5140
Page 4: ......
Page 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...