Chapter 3
Known Issues
27
TABLE 3-1
Hardware and Mechanical Issues
CR ID
Description
Workaround
6901327
In Solaris 10 10/09, after the RAID 1 build, label
information may fail to be written correctly.
1. Start the Solaris OS with single user mode, or from
the SunInstaller.
When booting from the SunInstaller, terminate the
SunInstaller once.
2. Use the
format -e
command to execute the
following 2-1 to 2-3.
2-1) Label the target disk with SMI label.
2-2) Label the target disk with EFI label.
2-3) Label the target disk with SMI label.
6823163
In servers with 8- and 16-disk backplanes, the 32GB
SATA SSD drive may not install in some drive bay
slots.
1. Loosen all the screws on the backplane.
2. Install SSDs in the corner drive bays.
3. Tighten all backplane screws.
4. Install remaining SSDs (if any).
6793093
When using a Type 6 keyboard attached directly to
the server, the server might hang during initial boot.
Only Type 7 keyboards are supported for local
connections. Do not use any other keyboard type.
6713773
6724347
A fault in the XAUI card causes the built-in Ethernet
port to be unusable.
If, in an environment where an XAUI card is
installed, the XAUI card becomes faulty, not only the
XAUI card, but also the built-in Ethernet port
(component name MB/GBE) is disabled during a
POST run. As a result, the built-in Ethernet port
becomes unusable.
None.
For display samples and recovery procedure, see
6706976
At write to CD/DVD media, there may be cases
where the writing speed may not reach the maximum
speed supported by the CD/DVD drive. Even if the
maximum operation is not reached, there are no
problems in the processing for writing to the
CD/DVD media.
Use the media as is.
6687915
6687916
Components inside the chassis get hot and some
components have sharp edges.
When servicing the server, be careful working inside
the chassis. For example, let the server cool down for
a few minutes before performing service procedures,
and avoid contact with the heat sink on the
motherboard.
6677336
When removing or replacing the air duct, the
capacitor on the DC to DC converter can be
damaged.
Use care not to hit or shock components on the
motherboard while removing or replacing the air
duct.
Summary of Contents for SPARC Enterprise T5140
Page 4: ......
Page 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...