Incorrect Operating Input Voltage Values for the 1.4
GHz, 8-Disk Configuration
The table that describes input power requirements for the SPARC Enterprise T5240 server
configuration with 1.4 GHz CPUs and an 8-disk capable backplane states the wrong
operating input voltage value in two places. The following table describes the necessary
correction.
Note –
The operating input voltage range for the DC input model is correct.
Note –
The 200 to 240 VAC operating input voltage range is required only for servers
equipped with 16-disk capable backplanes. All other configurations support the 100 to 240
VAC operating voltage range.
Incorrect Operating Input Power and Heat Dissipation
for the 1.4 GHz, 16-Disk Configuration
The table that describes input power requirements for the SPARC Enterprise T5240 server
configuration with 1.4 GHz CPUs and an 16-disk capable backplane states some wrong
values for DC input model. The following table describes the necessary correction.
Location of Incorrect Values
Incorrect Value
Correct Value
Table for T5240 Server, 1.4 GHz CPU, 8-disk backplane
Operating input voltage range
200 to 240 VAC
100 to 240 VAC
Maximum operating input power
At 200VAC 1161.1W
At 100VAC 1161.1W
Location of Incorrect Values
Incorrect Value
Correct Value
Table for T5240 Server, 1.4 GHz CPU, 16-disk backplane
Maximum operating input power
At -40 VDC: 1030.4 W
At -48 VDC: 1130.4 W
Maximum heat dissipation
3857.23 BTU/hour
(3753.1 KJ/hour)
3857.1 BTU/hour
(4069.4 KJ/hour)
Summary of Contents for SPARC Enterprise T5140
Page 4: ......
Page 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...