SPARC Enterprise T5140 and T5240 Servers Product Notes • November 2012
6781831
After enabled the NTP function of ILOM firmware,
when you power on the host, the Solaris OS time may
be lagged compared to the adjusted accurate time of
ILOM firmware.
Example of Solaris OS system log when the time
went backward for several tens of seconds
Nov 29 19:59:24 XXX genunix: [ID 904073
kern.notice] done
Nov 29 19:58:23 XXX genunix: [ID 540533
kern.notice] ^MSunOS Release 5.10
Version Generic_137137-09
64-bit
Note - Fixed in System Firmware 7.2.2.e or later.
When the Solaris OS time lagged, restore it according
to the following steps.
1. Shut down the system.
#
shutdown -y -i0 -g0
2. Start the system in the single user mode.
{0} ok boot -s
3. Set the system time.
#
date
setting time
4. Reboot the system.
#
shutdown -y -i6 -g0
6781815
After the ILOM reset or the power cord removal and
insertion, when the server powered on, Solaris OS
startup at the
ok
prompt of OpenBoot PROM (OBP)
using the
boot
command may fail.
Error output example:
{0} ok
boot
ERROR: All device paths in boot-
device have failed. (*)
{0} ok
It cannot refer to the device paths that configured in
the OpenBoot PROM environmental variable
boot-
device
and fails to start Solaris OS.
Note - Fixed in System Firmware 7.2.2.e or later.
After the ILOM reset or the power cord removal and
insertion, when you power on the server, check the
OpenBoot PROM environmental variable. Especially, in
case the OpenBoot PROM environmental variable
use-nvramrc?
has been set to
true
, it is necessary
in advance of starting the Solaris OS to see the
ok
prompt and check that
use-nvramrc?
has been set to
true
and then execute the
boot
command.
Confirmation example:
{0} ok
printenv use-nvramrc?
use-nvramrc? = true
{0} ok
6743343
Test Alert generation (alert test transmission) may not
be possible, depending on the "Alert Type" and
"Event" under the alert rule settings.
Note - Fixed in System Firmware 7.2.2.e or later.
None.
6738989
The SNMP tab of the ILOM Web interface does not
have an item for setting
engineid
.
Note - Fixed in System Firmware 7.2.2.e or later.
Use the
"set /SP/services/snmp engineid=
(value)
" command from the CLI to set
engineid
.
6733632
When the ILOM "
show -level all /SYS
"
command is executed, information under
/SYS/MB/SP
is not displayed.
When "
show -level all /SYS/MB
" is
executed, information under
/SYS/MB/SP
is not
displayed either.
Note - Fixed in System Firmware 7.2.2.e or later.
Use the
show /SYS/MB/SP
command.
6720583
When the role is changed to Administrator/Operator
using "Active directory" on the ILOM Web interface,
the Role field is still blank.
Note - Fixed in System Firmware 7.2.2.e or later.
Log in to ILOM and verify the
defaultrole
setting
in
/SP/clients/activedirectory
.
TABLE A-9
Issues Fixed in System Firmware 7.2.2.e or Later
(Continued)
CR ID
Description
Workaround
Summary of Contents for SPARC Enterprise T5140
Page 4: ......
Page 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...