When connected to OS console via ILOM, input or
display to console may not be enabled. And at this
time, output from Solaris OS to console may fail.
Note - Fixed in System Firmware 7.3.0.c or later.
After the system stop, disconnect the power cord and
then reconnect the power cord.
6983799
6981373
6946636
6908024
6722602
6663105
The login from SSH client to ILOM fails. Or, you
may fail to execute the ILOM command.
When this problem occurs, the following problems
may occur subsequently.
1. The login from SSH client (Secure Shell) to ILOM
fails.
2. The forcible dump order to OS fails.
3. The power-off order from ILOM fails.
4. The power-on order from ILOM fails.
5. The Solaris OS condole can not be obtained. Or,
you can not enter anything after entering "y".
Note - Fixed in System Firmware 7.3.0.c or later.
Power off the system, disconnect the power cord, wait
for about 180 seconds, and then reconnect the power
cord.
6972360
With System Firmware 7.2.10 or later, when you
connect the T5240 server which has the 1.6 GHz
CPU and of 8-disk configuration to the 100V power
supply and power on the system, a message might be
displayed in the Solaris OS system log. Also,
warning will be displayed in the
prtdiag -v
command execution result. For details, see
Note - Fixed in System Firmware 7.3.0.c or later.
None.
Due to the ILOM firmware bug, the input voltage
threshold value (noncritical) of the system which has
the 1.6 GHz CPU and of 8-disk configuration contains
an error.
If no faults are detected by executing commands like
show faulty command, ignore the output messages and
the displayed warnings.
6962499
After you remove/insert the power cord and while
POST is running, the "
/SYS/XXXXX prom is
unreadable or corrupted
" message may
appear and stop at
ok
the Power Cord Removal/Insert, an Error Message
May Appear during the POST (CR 6962499)” on
page 79
Note - Fixed in System Firmware 7.3.0.c or later.
Take 180 or more seconds for each of the intervals
between the system power-off and the power cord
removal, and between the removal and insertion of the
power cord.
6922544
When the timezone of the ILOM time has been set to
other than GMT, if you set the ILOM time and then
remove and insert the power cord, the ILOM set time
and the Solaris OS startup time may become
inaccurate.
Note - Fixed in System Firmware 7.3.0.c or later.
After you set the ILOM time, perform the ILOM reset
before you remove and insert the power cord and start
the Solaris OS.
TABLE A-4
Issues Fixed in System Firmware 7.3.0.c or Later
(Continued)
CR ID
Description
Workaround
Summary of Contents for SPARC Enterprise T5140
Page 4: ......
Page 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...