124
SPARC Enterprise T5140 and T5240 Servers Product Notes • November 2012
Workaround:
None. Connect the LAN cable to the NET-MGT port of ILOM and then set
the network configuration.
For DC Input Power Models, /PS0/AC_POK Is
Displayed (CR 6815369)
For DC input power models, /PS0/AC_POK and /PS0/DC_POK identify sensors in the
power supply units. /PS0/AC_POK does not represent an AC power supply unit.
For example, the following event log is collected when the DC power cord is disconnected or
reconnected:
[When the DC power cord is disconnected]
[When the DC power cord is reconnected]
->
show /SP/network/ -d properties
/SP/network
Properties:
commitpending = (Cannot show property)
dhcp_server_ip = none
ipaddress = (none)
ipdiscovery = (none)
ipgateway = (none)
ipnetmask = (none)
macaddress = (none)
pendingipaddress = 192.9.200.33
pendingipdiscovery = static
pendingipgateway = (none)
pendingipnetmask = 255.255.255.0
state = disabled
IPMI |minor : "ID = 1cec : 02/06/2009 : 04:00:26 : Power Supply
: /PS0/AC_POK : State Deasserted" <--(*)
IPMI |minor : "ID = 1ced : 02/06/2009 : 04:00:26 : Power Supply
: /PS0/DC_POK : State Deasserted"
IPMI |minor : "ID = 1cee : 02/06/2009 : 04:00:26 : Power Supply
: /PS0/FAIL : State Asserted"
IPMI |minor : "ID = 1cef : 02/06/2009 : 04:00:59 : Power Supply
: /PS0/AC_POK : State Asserted" <--(*)
IPMI |minor : "ID = 1cf0 : 02/06/2009 : 04:00:59 : Power Supply
Summary of Contents for SPARC Enterprise T5140
Page 4: ......
Page 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...