Appendix A
Fixed Issues
79
Excerpt from the
prtdiag -v
command execution result:
Workaround:
None. Due to the ILOM firmware bug, the input voltage threshold value
(noncritical) of the system which has the 1.6 GHz CPU and of 8-disk configuration contains
an error. If no faults are detected by executing commands like show faulty command, ignore
the output messages and the displayed warnings.
After the Power Cord Removal/Insert, an Error Message May
Appear during the POST (CR 6962499)
This issue is resolved by updating the system firmware to 7.3.0.c or later.
After you remove/insert the power cord and while POST is running, the "
/SYS/XXXXX
prom is unreadable or corrupted
" message may appear and stop at
ok
prompt.
Message example:
Voltage sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/MB V_+3V3_STBY ok
SYS/MB V_+3V3_MAIN ok
SYS/MB V_+12V0_MAIN ok
SYS/MB V_VDDIO ok
SYS/MB V_VCOREL ok
SYS/MB V_VCORER ok
SYS/MB V_+1V5_IO ok
SYS/MB V_VMEML ok
SYS/MB V_VMEMR ok
SYS/MB V_VBAT ok
SYS/PS0 V_IN_MAIN warning (103.200volts )
~~~~~~~~~~~~ voltage value
SYS/PS0 V_OUT_MAIN ok
SYS/PS1 V_IN_MAIN warning (103.200volts )
~~~~~~~~~~~~ voltage value
SYS/PS1 V_OUT_MAIN ok
Chassis | major: Host has been powered on
0:0:0>
0:0:0>SPARC-Enterprise[TM] T5140/T5240 POST 4.30.6 2009/12/01 13:08
/export/delivery/delivery/4.30/4.30.6/post4.30.6-micro/Niagara/huron/integrated
(root)
0:0:0>Copyright 2009 Sun Microsystems, Inc. All rights reserved
Summary of Contents for SPARC Enterprise T5140
Page 4: ......
Page 34: ...24 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 56: ...46 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 72: ...62 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...
Page 138: ...128 SPARC Enterprise T5140 and T5240 Servers Product Notes November 2012 ...