842
Upgrade and Maintenance Manual
TX300 S7 / RX350 S7
Converting a tower server to a rack server
15.7 Removing glider feet
Figure 564: Removing glider feet
Ê
Using a slotted screw driver, slightly pry up on each glider foot until it
detaches.
Ê
Bring the server back to its horizontal position.
I
At least two people are needed to turn over a fully equipped server.
Remove hard disk drives and power supply modules in order to
facilitate the task.
15.8 Preparing the intrusion switch
Ê
Remove the intrusion switch module as described in section
"Removing the
intrusion switch cable" on page 868
.
Ê
Attach a rubber bumper (C26192-Y26-C43) to the front intrusion switch and
reinstall the intrusion switch module as described in section
"Installing the
intrusion switch cable" on page 871
.
Summary of Contents for PRIMERGY TX300 S7
Page 6: ...Upgrade and Maintenance Manual TX300 S7 RX350 S7 ...
Page 32: ...32 Upgrade and Maintenance Manual TX300 S7 RX350 S7 ...
Page 36: ...36 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Introduction ...
Page 162: ...162 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Basic software procedures ...
Page 188: ...188 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Power supply ...
Page 396: ...396 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Fans ...
Page 548: ...548 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Main memory ...
Page 752: ...752 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Front panel and external connectors ...
Page 822: ...822 Upgrade and Maintenance Manual TX300 S7 RX350 S7 System board and components ...
Page 876: ...876 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Cabling ...