166
Upgrade and Maintenance Manual
TX300 S7 / RX350 S7
Power supply
6.1.2
Assembly rules
– Mixed assembly of 450 W and 800 W PSU modules is not possible.
– PSU slots 1 or 2 always need to be equipped with a PSU module.
– Always install dummy modules into unused PSU slots to comply with
applicable EMC regulations and satisfy cooling requirements.
6.1.3
PSU indicator
Figure 72: PSU indicator
Indicator Status
Description
1
PSU operating
status
green on
Server is switched on and functioning
properly
green
flashing
Server is switched off, main voltage is
present (Standby mode)
orange on
PSU failure (over / under voltage, over
temperature or fan failure)
orange
flashing
Overload warning