66
Upgrade and Maintenance Manual
TX300 S7 / RX350 S7
Basic hardware procedures
I
In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer replaceable unit or if a
service technician needs to be dispatched to replace the part (see
section
"Determining the error class" on page 61
).
If the system has been powered off to replace a non hot-plug unit, a
system of PRIMERGY diagnostics indicators guides you to the faulty
component.
D
PCI card
off
PCI card operational
orange on
PCI card failure
E
CPUs
off
CPUs operational
orange on
CPU failure
F
Memory
off
memory module operational
orange on
memory module failure
G
PSUs
green on
PSUs operational
H
orange on
PSU failure
I
Main power
green on
main voltages are within range
K
Standby power yellow on
standby voltages are within range
L
iRMC
green
flashing
iRMC S3 management controller is
operational
M
System fans
off
fan running
orange on
fan failure
N
Battery
orange on
battery failure
Indicator Status
Description
Summary of Contents for PRIMERGY TX300 S7
Page 6: ...Upgrade and Maintenance Manual TX300 S7 RX350 S7 ...
Page 32: ...32 Upgrade and Maintenance Manual TX300 S7 RX350 S7 ...
Page 36: ...36 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Introduction ...
Page 162: ...162 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Basic software procedures ...
Page 188: ...188 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Power supply ...
Page 396: ...396 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Fans ...
Page 548: ...548 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Main memory ...
Page 752: ...752 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Front panel and external connectors ...
Page 822: ...822 Upgrade and Maintenance Manual TX300 S7 RX350 S7 System board and components ...
Page 876: ...876 Upgrade and Maintenance Manual TX300 S7 RX350 S7 Cabling ...