5.1 Overview of Main Unit Operator Panel
Note1: auto boot: The Solaris Operating Environment automatically starts up when
main power is turned on.
boot stop: The system stops in OBP mode when main power is turned on.
The Solaris Operating Environment is not activated.
Note2: The F7973RC1 is sold only in Japan.
Note3: For information about the contents of the status indication LCD and
operation of switches, see
Section 5.2, "Display Format of Operator Panel."
If the operating system (OS) is running when a Poff operation (described above) is
initiated, the OS starts its shutdown sequence, and the main unit power is turned off
after shutdown.
Remote
Pon/Poff
(Note1)
Pon/Poff by the
power switch
Only power-on is
enabled
(auto boot)
Enabled
(boot stop)
Enabled
(boot stop)
Pon/Poff by the
SMC
Enabled
(auto boot)
Enabled
(boot stop)
Enabled
(boot stop)
Pon/Poff by the
F7973RC1 (Note2)
Enabled
(auto boot)
Enabled
(boot stop)
Disabled
Partition start-up
command (up) by the
panel (Note3)
Enabled
(auto boot)
Enabled
(boot stop)
Enabled
(boot stop)
Pon/Poff by the
automatic power
control
Enabled
(auto boot)
Enabled
(boot stop)
Disabled
Table 5.1 Mode switch settings and functions