Chapter 9 Operation and Maintenance
9.5 Troubleshooting
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
210
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
Procedure
1
Press the controller enclosure’s Power Switch for four seconds or more to turn off the
ETERNUS DX60/DX80/DX90.
Drive enclosures with no miniSAS cables connected will remain on.
2
Connect the miniSAS cable while the drive enclosure is on.
3
Press the controller enclosure’s Power Switch to turn on the ETERNUS DX60/DX80/
DX90.
End of procedure
●
When the general status of GUI is
Check whether the miniSAS cables (for drive enclosures) are connected in the correct order.
If not, reconnect the miniSAS cables in the following order.
Procedure
1
Press the controller enclosure’s Power Switch for four seconds or more to turn off the
ETERNUS DX60/DX80/DX90, and turn off the AC power.
2
Re-connect the miniSAS cable.
3
Make sure that power is being supplied, then turn the ETERNUS DX60/DX80/DX90 on.
End of procedure
■
When the FAULT LED blinks
Check the General Status in GUI. A General Status of
indicates that the ETERNUS
DX60/DX80/DX90 contains a component that requires preventive maintenance.
Use the Storage System Status screen's device tree to check the detailed information on the
component whose
image is on, and contact your maintenance engineer.
When checking the general status and detailed information on products via
CLI, refer to "ETERNUS DX60/DX80/DX90 CLI User Guide".
Refer
"ETERNUS DX60/DX80/DX90 CLI User Guide"