Chapter 6 Cable Connection
6.7 Power Cord Connection
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
135
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
3
Use the power cord clamps to prevent the power plugs from coming unplugged.
Attach the power cord clamps removed in
4
Connect the power cords (AC input cables) (4m) supplied with the AC outlet box
to the inlet of the AC outlet box.
The AC outlet box is shipped with the power cord connected to the
inlets.
IMPORTANT
Connecting the power cords (AC input cables) to different power
systems, on the AC outlet box A and C, and the AC outlet box B and
D sides respectively, prevents power supply facility failures.
WARNING
Do Not
•
Do not connect power cords or other cables during
thunderstorms, as lightning can result in fire or electric shock.
CAUTION
Do
•
Be sure to fully insert each plug into its socket. Failure to do
so may lead to fire or electrical shock.
Do Not
•
When disconnecting the power plug, be sure to pull from the
plug and not the cord. Pulling the cord may expose or snap
the inner wires, which can lead to fire or electrical shock.
•
Do not use the server service outlet to connect the device
power cord.
Connect to power outlets.
AC input cables