Chapter 9 Operation and Maintenance
9.4 Post Start-of-Operation Changes to the Configuration
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
207
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
9.4.3
Replacing SAS Cards
The following explains how to replace a failed SAS card.
Note that this is only an overview of the replacement procedure. Refer to the relevant manuals
for more details.
The procedure to replace a SAS card is as follows:
Procedure
1
Before performing this procedure, use the ETERNUS DX60/DX80's GUI or CLI
to check the SAS address or host affinity of the SAS card that is to be replaced,
and record this setting for later replication.
2
Replace the server-side SAS card.
2-1
Turn off the server whose SAS card is to be replaced.
2-2
Replace the SAS card.
For details of the replacement procedure, refer to the user guide attached with the SAS
card.
3
Adjust the settings as necessary, using the ETERNUS DX60/DX80's GUI or CLI.
3-1
Delete the SAS address or host affinity setting assigned to the removed SAS card.
3-2
Referring to the information recorded in
, register the SAS address or host
affinity of the new SAS card in the ETERNUS DX60/DX80.
4
When the setting is complete, confirm that the server can access the ETERNUS
DX60/DX80.
End of procedure
Refer
User guide for SAS card
"ETERNUS Disk storage systems User’s Guide -Server Connection-"