Chapter 6 Cable Connection
6.2 LAN Cable Connection (for Operation Management)
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
110
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
■
LAN cable connection procedure
The following explains how to connect the LAN cable.
Procedure
1
Connect the LAN cable to the ETERNUS DX60/DX80/DX90.
Connect the LAN cable connectors to the MNT ports of the controller 0 (CM#0) and
controller 1 (CM#1) for the ETERNUS DX60/DX80/DX90.
2
Connect the LAN cables to the networking equipment.
Connect the other end of the LAN cable to the networking equipment, such as hub or
router. For
networking
equipment connection details, refer to the documentation for the
networking
equipment being connected to.
IMPORTANT
•
To help with LAN cable management and prevent incorrect connections,
attach labels to the LAN cables and make a note of connection origins
and destinations.
•
When connecting LAN cables, check the connector orientation and then
firmly push it all the way in.
When disconnecting LAN cables, depress the tab, then pull out the
connector.
This section describes dual controller model as an example. Note that there
is only controller 0 (CM#0) for single controller model.
CAUTION
Do
•
When connecting the LAN cables, position them so that they
will not obstruct replacement of the power supply unit or
controllers by the maintenance engineer.