Chapter 7 Setup
7.4 Monitoring Setup
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
177
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
2-3
Enter a new destination for the SNMP Trap, and click the [Add New Destination] button.
-
Enter the IP address of the ServerView management device (SNMP Manager) in
"IP Address".
-
Enter the Community name to transfer the SNMP Trap to (if not specified, "public" is
used) in "Community Name".
Figure 7.38 [Trap] screen
The new destination for the SNMP is added in the "Set Destination of SNMP Traps"
field.
2-4
Click the [Set] button.
A confirmation screen appears.
2-5
Click the [OK] button.
The settings are reflected.
3
Download the MIB definition file for SeverView monitoring.
Export the MIB definition file for ServerView monitoring (FJDARY-E60.MIB) in the
ETERNUS DX60/DX80/DX90.
3-1
Click the [Download MIB File] under the [Network Settings] menu on the [Global
Settings] tab in the GUI screen.
The [Download MIB File] screen appears.