Chapter 1 Overview
1.2 Configuration
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
26
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
1.2
Configuration
This chapter describes items to be noted before configuring the ETERNUS DX60/DX80/DX90
systems.
1.2.1
RAID Level
This section describes the supported RAID level and usage (RAID level selection criteria), and
RAID group configuration.
■
Supported RAID levels and mechanism
The ETERNUS DX60/DX80/DX90 supports the following RAID levels.
•
RAID0 (striping)
•
RAID1 (mirroring)
•
RAID1+0 (striping of pairs of disks for mirroring)
•
RAID5 (striping with distributed parity blocks)
•
RAID5+0 (double striping with distributed parity blocks)
(*1)
•
RAID6 (striping with distributed double parity blocks)
(*2)
*1:
RAID5+0 is a RAID system in which the data on RAID5 volumes is then RAID0 striped.
*2:
RAID6 ensures data safety and continues system operation in the case of a second
malfunction within a single RAID group.
CAUTION
Do
•
Remember that a RAID0 configuration is not redundant. This means
that if a RAID0 disk fails, the data will not be recoverable.
Therefore, using RAID1, RAID1+0, RAID5, RAID5+0, or RAID6
configuration is recommended.