Chapter 2 Components
2.1 3.5" Type Controller Enclosure
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
56
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
■
Power supply unit
shows the power supply unit.
Figure 2.10 Power supply unit (3.5" type controller enclosure)
Each power supply unit has two internal cooling fans.
IMPORTANT
•
Each enclosure has two power supply units (PSU#0 and PSU#1). The
power cords must be connected to the inlets of both power supply units.
•
Power cords should not be reconnected immediately after being
disconnected. Always wait for the power supply unit's STATUS LED to
completely turn off (about 10 seconds) before reconnecting a
disconnected power cord.
STATUS LED
Blinks green ( ) when AC power is supplied (power cord is connected)
but DC power is turned off.
Glows green ( ) when AC power is supplied (power cord is connected)
and DC power is turned on.
Glows orange ( ) to indicate a fault has been detected in a fan
or power supply.
Inlet
Power cord connects here.