Chapter 7 Setup
7.2 Basic Setup
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
148
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
■
For SAS
On the [Set SAS Port Parameters] screen, set the information for the connection (detailed
SAS port information) between the ETERNUS DX60/DX80 SAS port and the server.
(1)
Select a port and specify the necessary items in "Port Settings", and click the [Next >]
button.
Figure 7.9
[Set SAS Port Parameters] screen
A confirmation screen appears.
(2)
Click the [OK] button.
The port parameters are set, and the [Setup Network Environment] screen appears.
7
Set the network environment.
Set the ETERNUS DX60/DX80/DX90 environment for network communication.
7-1
Set the necessary parameters such as a MNT port IP address, subnet mask and
default gateway, and click the [Next >] button.
IMPORTANT
Never set all of the "Interface" fields ("http", "https", "telnet",
"SSH", "Maintenance", "Maintenance-Secure", and "ICMP") to
"Disable". If this is done, network access to the device becomes
impossible.
If the device becomes inaccessible in this way, pressing the
Controller Enclosure's IP RESET Switch twice in succession
within a two second interval will reset it to its factory default
settings, and reallow network access.