Chapter 3 Standard Operations
3.5 Turning the AUTO POWER Switch On/Off
ETERNUS DX60/DX80/DX90 Disk storage system User Guide
79
Copyright 2011 FUJITSU LIMITED
P3AM-3042-08ENZ0
2
Tighten the thumb screw to fasten the flange cover.
End of procedure
■
Procedure for removing the flange cover
Loosen the thumb screw to remove the flange cover.
3.5
Turning the AUTO POWER Switch On/Off
This section explains how to enable the AC automatic linkage mode by turning the AUTO
POWER switch of the controller enclosure to "ON".
When AC automatic linkage mode is enabled, the ETERNUS DX60/DX80/DX90 is automatically
turned on when the power supply recovers after a power failure.
When the AUTO POWER switch of the controller enclosure is set to "OFF", the AC automatic
linkage mode is disabled.
Procedure
1
Remove the front cover from the 3.5" type controller enclosure.
Remove the flange cover from the 2.5" type controller enclosure.
For details on how to remove the front cover, refer to
"3.3 Attaching and Removing the
For details on how to remove the flange cover, refer to
"3.4 Attaching and Removing the
.
2
Turn the AUTO POWER switch of the controller enclosure to "ON".
Push up the AUTO POWER switch to the "ON" side using the pin that is provided with the
ETERNUS DX60/DX80/DX90.
Thumb screw