5-40
5-3 I/O Area of NP1F-MP2
)
t
e
s
e
r
r
e
t
n
u
o
c
e
u
l
a
v
t
n
e
r
r
u
c
o
t
e
s
n
o
p
s
e
R
:
e
m
a
n
l
a
n
g
i
S
(
4
t
i
B
<Description>
• This is a response signal to the current value counter reset command or command pulse register reset commands
in the pulse generation mode.
This signal becomes “1” while the current value counter reset command or command pulse register reset
command is “1.”
Current value counter reset command
(PC == > MP2)
Command pulse register reset command
(PC == > MP2)
Response to current counter reset
(PC <== MP2)
“1”
“1”
“1”
Current value counter
is reset.
“1”
FIFO buffer for command
pulse register is reset.
• In the position command mode, when the command pulse register reset command is issued, the start signal is
turned OFF, and pulse output is stopped.
The response to reset command becomes “1,” corresponding to the command pulse reset command.
)
g
n
i
g
n
a
h
c
d
e
e
p
S
:
e
m
a
n
l
a
n
g
i
S
(
5
t
i
B
<Description>
• This is a response signal to the speed change command in the pulse generation mode.
While this signal is “1,” the values stored in the set value data area are continuously written in the “target frequency
register.”
Frequency (speed) data can be changed from the CPU module.
(For details, refer to the paragraph for speed change command.)
• In the position command mode, this signal continues to be “0.”
Summary of Contents for micrex-sx NP1F-MP1
Page 1: ...FEH214a series USER S MANUAL PULSE TRAIN POSITIONING CONTROL COMBINED MODULE...
Page 28: ...3 10 3 4 Dimensions 3 4 1 NP1F MP1 for 1 axis 3 4 2 NP1F MP2 for 2 axes 90 46 5 75 35 105...
Page 29: ...3 11 3 4 Dimensions 3 4 3 NP2F LEV Signal converter 95 47 2 10 29 8 39 8 85 95 40 36 6...
Page 223: ...Section 8 Troubleshooting Page 8 1 LED Indication 8 1 8 2 Error Indication 8 2...