7-8
7-3 Functions of Pulse Generation Mode
7-3-4 Trapezoidal acceleration/deceleration
• This module (NP1F-MP1/NP1F-MP2) executes the processing for trapezoidal acceleration/deceleration using the
acceleration/deceleration register.
Compare
Decelerate
Constant speed
Accelerate
Acceleration/
deceleration
register
1 / n
2
(Current frequency)
20-bit up/down counter
25MHz
Target frequency
• When automatic acceleration/deceleration is enabled (by the control register), the 20-bit-length up/down counter
operates as follows. (For details, refer to the paragraph for control register in Section 6.)
• Before the deceleration point is detected
Target frequency register > Current frequency register ==> Count up (acceleration)
Target frequency register < Current frequency register ==> Count down (deceleration)
Target frequency register = Current frequency register ==> Hold (constant speed)
• After the deceleration point is detected
Base frequency register > Current frequency register ==> Count up (acceleration)
Base frequency register < Current frequency register ==> Count down (deceleration)
Base frequency register = Current frequency register ==> Hold (constant speed)
• The time until maximum output frequency is reached since the pulse output has been stopped (0Hz) is calculated
by the following formula. (Setting range of acceleration/deceleration register: 1 to 65535)
• When the frequency register is of 16-bit length
Acceleration/deceleration time (ms) = 65,535 / {25,000kHz / (Set value of acceleration/deceleration re 1)}
In this case, the minimum time until maximum output frequency is reached since the pulse output has been
stopped is:
Acceleration/deceleration time = 65,535 / 25,000kHz / 2 = 5.2ms
• When the frequency register is of 20-bit length
Acceleration/deceleration time (ms) = 1,048,575 / {25,000kHz / (Acceleration/deceleration re 1)}
In this case, the minimum time until maximum output frequency is reached since the pulse output has been
stopped is:
Acceleration/deceleration time = 1,048,575 / 25,000kHz / 2 = 84ms
Summary of Contents for micrex-sx NP1F-MP1
Page 1: ...FEH214a series USER S MANUAL PULSE TRAIN POSITIONING CONTROL COMBINED MODULE...
Page 28: ...3 10 3 4 Dimensions 3 4 1 NP1F MP1 for 1 axis 3 4 2 NP1F MP2 for 2 axes 90 46 5 75 35 105...
Page 29: ...3 11 3 4 Dimensions 3 4 3 NP2F LEV Signal converter 95 47 2 10 29 8 39 8 85 95 40 36 6...
Page 223: ...Section 8 Troubleshooting Page 8 1 LED Indication 8 1 8 2 Error Indication 8 2...