8-2 Error Indication
r
o
r
r
e
d
e
t
a
l
e
r
-
e
l
u
d
o
m
l
o
r
t
n
o
c
g
n
i
n
o
i
t
i
s
o
P
)
8
Sample system configuration
Event:
· Servo motor does not rotate (under no load.)
· Unit servo motor works.
1) Positioning control module
RDY
LED
On
ALM
LED Off
ONL
LED On
ERR
LED Off
EMG LED Off
+OT
LED Off
-OT
LED Off
2) CPU module
ONL
LED
On
ERR
LED
Off
RUN
LED
On
ALM
LED
Off
3) I/O module
ONL
LED
On
ERR
LED
Off
· Wrong wiring
· User program error
· Servo amplifier is off-line.
· Servo amplifier requires special setting (for example, to enable pulse train)
Cause:
· Check the wiring.
· Check the user program
· Check the setting of the servo amplifier.
Remedy:
:
SX bus terminating plug (NP8B-BP) x 2
Servo
amplifier
Encoder
Motor
(-OT)
(LS)
(+OT)
Input module
Output module
Positioning
control module
Power supply
module
CPU module