168
PB
APPENDIX
Appendix 1: Reference Sheet of Celsius and Farenheit
.
temperature
display
Fahrenheit
Fahrenheit Celsius
temperature
display
Fahrenheit
Fahrenheit Celsius
display
temperature
Fahrenheit
Fahrenheit
32/33
Celsius
32
0
55/56
55.4
13
79/80
78.8
26
34/35
33.8
1
57/58
57.2
14
81
80.6
27
36
35.6
2
59/60
59
15
82/83
82.4
28
37/38
37.4
3
61/62
60.8
16
84/85
84.2
29
39/40
39.2
4
63
62.6
17
86/87
86
30
41/42
41
5
64/65
64.4
18
88/89
87.8
31
43/44
42.8
6
66/67
66.2
19
90
89.6
32
45
44.6
7
68/69
68
20
91/92
91.4
33
46/47
46.4
8
70/71
69.8
21
93/94
93.2
34
48/49
48.2
9
72
71.6
22
95/96
95
35
50/51
50
10
73/74
73.4
23
97/98
96.8
36
52/53
51.8
11
75/76
75.2
24
99
98.6
37
54
53.6
12
77/78
77
25
temperature
Fahrenheit
display
Fahrenheit Celsius
display
Fahrenheit
temperature
Fahrenheit Celsius
display
Fahrenheit
temperature
Fahrenheit
61
Celsius
60.8
16
69/70
69.8
21
78/79
78.8
26
62/63
62.6
17
71/72
71.6
22
80/81
80.6
27
64/65
64.4
18
73/74
73.4
23
82/83
82.4
28
66/67
66.2
19
75/76
75.2
24
84/85
84.2
29
68
68
20
77
77
25
86
86
30
Appendix 2: Configuration of Connection Pipe
Diameter of connection pipe
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Outdoor unit throttle
Liquid pipe(inch)
Gas pipe(inch)
Cooling only(oz/ft.)
Cooling and heating(oz/ft.)
Ф1/4
Ф3/8or Ф1/2
0.2
0.2
Ф1/4 or Ф3/8
Ф5/8 or Ф3/4
0.2
0.2
Ф1/2
Ф3/4 or Ф7/8
0.3
1.3
Ф5/8
Ф1 or Ф1 1/4
0.7
1.3
Ф3/4
/
2.7
2.7
Ф7/8
/
3.8
3.8
Cooling capacity
Max height
Max length of
connection pipe
5000 Btu/h(1465 W)
difference
49.21ft
16.40ft
7000 Btu/h(2051 W)
49.21ft
16.40ft
9000 Btu/h(2637 W)
49.21ft
32.81ft
12000 Btu/h(3516 W)
65.62ft
32.81ft
18000 Btu/h(5274 W)
80.02ft
32.81ft
24000 Btu/h(7032 W)
80.02ft
32.81ft
28000 Btu/h(8204 W)
98.43ft
32.81ft
36000 Btu/h(10548 W)
98.43ft
65.62ft
42000 Btu/h(12306 W)
98.43ft
65.62ft
48000 Btu/h(14064 W)
98.43ft
65.62ft
1.Standard length of connection pipe
16.40ft, 24.61ft, 26.25ft.
2.Min. length of connection pipe is 9.84ft.
3.Max. length of connection pipe and max. high difference.
4.The additional refrigerant oil and refrigerant charging required after
prolonging connection pipe
basis of standard length, you should add 5ml of refrigerant oil for each
additional 16.40ft of connection pipe.
the basis of liquid pipe):
The calculation method of additional refrigerant charging amo
unt (on
After the length of connection pipe is prolonged for 32.81ft at the
When the length of connection pipe is above 16.40ft, add refrigerant according to the prolonged length of liquid pipe. The
additional refrigerant charging amount per meter is different according to the diameter of liquid pipe. See the following sheet.
Additional refrigerant charging amount = prolonged length of liquid pipe X additional refrigerant charging amount per meter
Summary of Contents for FSHW091
Page 8: ...8 INTRODUCTION FSHSW09A1A FSHSW12A1A Figure 102 Indoor Units FSHSW18A3A FSHSW24A3A FSHSW36A3A ...
Page 47: ...47 INSTALLATION ...
Page 48: ...48 INSTALLATION Installation Tools ...
Page 72: ...72 WIRED CONTROLLER Display ...
Page 122: ...122 TROUBLESHOOTING Malfunction of IDUFanMotorU8 Service Manual No Start End ...
Page 146: ...146 WIRING DIAGRAMS Figure 8054 9 12KOutdoorUnitWiringDiagrams 60000706067401 3 2 N 1 C3 C4 ...
Page 158: ...158 FIgure 906 PARTS CATALOG 9KOutdoorUnit 28 27 29 31 30 32 ...
Page 160: ...160 PARTS CATALOG 12k OutdoorUnit 28 27 29 31 30 32 FIgure 907 ...