REMOVAL
Indoor Unit
Procedure
Steps
Remove the screws fixing motor clamp
and then remove the motor clamp.
Screws
Screw
Motor clamp
Motor
Holder
sub-assy
Step motor
Remove the screws at the connection
place of cross flow blade and motor; lift
the motor and cross flow blade upwards
to remove them.
Remove the bearing holder sub-assy.
then remove the step motor.