Installation Instructions
16.1.09
Panda_6000i_System_eng_s01835.book.R01 - Chapter C: Installation Instructions Page 39
C.5 Water-cooled exhaust system
By injecting the outlet raw water into the exhaust manifold, the exhaust gases are cooled and the
noise emissions from the exhaust system are reduced.
C.5.1 Installation of the standard exhaust system
The generator exhaust system must remain completely independent and separate from the
exhaust system of any other unit(s) on board. The exhaust hose has an inner diameter of 30 mm.
The water lock must be installed at the lowest point of the exhaust system. An optional noise
insulated water lock can also be installed. The exhaust hose descends from the capsule to the
water lock. Then the hose rises via the "goose neck" to the silencer (see drawing). The goose
neck must be vertical and sit preferably along the ship's keel centre line. The exhaust system
must be installed so that the back pressure inside the exhaust does not exceed 0.4 bar (6 psi)
and total length does not exceed 6 m (20 ft.).
Exhaust diameter see section F.2, “Technical data,” on page 74.
Fig. C.5.1-1: Installation scheme standard exhaust system
1. Generator
2. Water lock
3. Goose neck
4. Silencer
5. Hull outlet
Summary of Contents for Panda 6000i PMS
Page 9: ...Panda 6000i PMS 230V 50Hz 6kW Fischer Panda GmbH Panda 6000i Part 1 Generator Manual ...
Page 14: ...14 Socket wrench set Hexagon wrench keys ...
Page 18: ...18 Intentionally Blank ...
Page 92: ...Panda iControl Page 92 Chapter A Panda iControl Panel_iControl_eng fm Intentionally Blank ...