Maintenance Instructions
16.1.09
Panda_6000i_System_eng_s01835.book.R01 - Chapter E: Maintenance Instructions Page 69
12.During the winter storage the upper section of the sound inulated capsule must be taken off, in
order to avoid condensed moisture formation, if traces of humidity remain in the sound insula-
tion capsule inside casing by leakages in the seawater circuit.
13.The generator housing and the housing of the engine should be sprayed with a corrosion pro-
tection oil before the winter storage. This procedure is recommended also in the season. This
procedure can avoid that arising and humidity marks on the surface of the aluminum construc-
tion units be noticed too late.
14.Disconnect the starter battery (positive and negative pole).
15.Lubricate the spindle for the number of revolutions adjustment device with a special lubricant
(Antiseize grease).
16.Check cooling water connection block at the generator housing on traces of corrosion and if
necessary renew. (Only such traces are to be considered, which refer to clear "blossoming" of
the material. If the surface is only grey coated, this is only an indication for the fact that alumi-
num came into contact with condensed moisture.)
17.Use of a air dehumidifier. The best way to protect a yacht in the winter storage against
damage by humidity is, to places a air dehumidifier inside the ship and locks all hatches. The
devices have a hygrometer, which switches the device off, if the humidity is under the adjusted
value. There is no better method, in order to protect pads, cable, electronics, wood, engines
etc. optimally against any rotting by humidity.
E.8.2 Initiation during spring
• Before starting, turn the engine once with the hand, in order to eliminate the beginnings of exi-
sting corrosion to the bushes. If necessarily carry out normal engine inspection.
• Change engine oil and engine oil filters.
• Reintegrate the impeller of the cooling water pump and check pump for leakage.
• Charge starter battery of the generator, connect cables and check battery voltage.
• Start generator and check the basic adjustments of the generator such as voltage, speed re-
gulation etc...
• Check all switching off devices for function by operational procedures.
Fischer Panda does not take over adhesion for possible damages!
E.8.1 Measures for preparation of winter storage
Summary of Contents for Panda 6000i PMS
Page 9: ...Panda 6000i PMS 230V 50Hz 6kW Fischer Panda GmbH Panda 6000i Part 1 Generator Manual ...
Page 14: ...14 Socket wrench set Hexagon wrench keys ...
Page 18: ...18 Intentionally Blank ...
Page 92: ...Panda iControl Page 92 Chapter A Panda iControl Panel_iControl_eng fm Intentionally Blank ...