Tables
Page 76 AGT-DC_PMS_144V_s01790_Operation instruction.R01 - Chapter F: Tables
16.1.09
Generatortype
Ø Cooling water conduit
Ø Exhaust con-
duit
[mm]
Ø Fuel conduit
Fresh water
[mm]
Raw water
[mm]
Supply
[mm]
Return
[mm]
Panda 6000i PMS
20
20
40
8
8
Table 3: Diameter of conduits
Wiring for vehicles.
single phase, not tin-plated, PVC-isolated.
nominal wire cross-section
[mm²]
allowed continous current (reference point)
a
a. DIN VDE 0298, part4.
at +30°C [A]
at +50°C [A]
1
19
13,5
1,5
24
17,0
2,5
32
22,7
4
42
29,8
6
54
38,3
10
73
51,8
16
98
69,6
25
129
91,6
35
158
112
50
198
140
70
245
174
95
292
207
120
344
244
Table 4: Cable cross-section