Panda PMGi 6000
Page 102 - Chapter A: Panda PMGi 6000
PGMi 6000_eng.fm
Fischer Panda Datasheet
Ferritring
Insert the cable comming from the generator about 10cm
through the ring.
Turn it back and insert it through again. (second time)
Turn it back and insert it through again. (Third time)
The ferrit should be as close to the PMGi as possible.
Secure the ferrit with teh cable straps or heat shrinkable
tube.
Mount the plug on the cable.
Fig. A.8.2-4: Installation of the ferrites
A.9 Technical Data
A.9.1 General Data
PMGi is part of the Panda i-series generator. It´s not allowed to be used with other generators or aplications.
Storage temperature
PMGi
-20°C to +55°C
Working temperature
PMGi
Minimum: -20°C
Maximum: +40°C
Maximale internel temperature of
the PMGi: +60°C
Table 2: General data
A.9.2 Generator Spezifikation
PMG Generator out
3 phase
Voltage Phase
minimum 250V AC
Maximum 550V AC
Frequency
minimum 250 Hz
Maximum 650 Hz
Table 3: Generator specification