A.1 Safety instructions
The generator may not be taken into use with the cover removed.
The rotating parts (belt-pulley, belts, etc) must be covered and protected so that there is no danger to life and
body!
If a sound insulation cover must be produced at the place of installation, then well-placed signs must show that
the generator can only be switched on with a closed capsule.
All servicing-, maintenance or repair work may only be carried out, when the motor is not running.
Electrical power: DANGER TO LIVE!
Electrical voltages above 48 volts (battery chargers greater than 36 volts) are always dangerous
to life). The rules of the respective regional authority must be adhered to. Only an electrician
may carry out installation of the electrical connections for safety reasons.
Before start working at the Panda i-series generator (service, repair ect), diconnect the starter battery (First minus
cable, then positive cable), so that the generator cannot be unintentionally started.
A.2 Connection of the iControl
To connect the iConrol use the original prepared cable.
(6 wires shilded)
Terminator
cablecolour 4000i
cablecolour 6000i
1. U+ cablecolour
brown
brown
2. Gnd cablecolour
brown-white
grey
3. RZL cablecolour
green
green
4. D_A cablecolour
blue
white
5. D_B cablecolour
blue-white
yellow
Between clamp RZL(3) und Gnd(2) an automatik start device (Battery monitor) can be connected
Fig. A.2-1: Connection of the iControl
1
3
5
2
4
Summary of Contents for Panda 6000i PMS
Page 9: ...Panda 6000i PMS 230V 50Hz 6kW Fischer Panda GmbH Panda 6000i Part 1 Generator Manual ...
Page 14: ...14 Socket wrench set Hexagon wrench keys ...
Page 18: ...18 Intentionally Blank ...
Page 92: ...Panda iControl Page 92 Chapter A Panda iControl Panel_iControl_eng fm Intentionally Blank ...