Chapter A: Panda PMGi 6000 - Page 99
Fischer Panda Datasheet
A.5 Operation manual
A.5.1 Primary remarks / Winter operation
The PGMi can operate in the range of -20°C to +40°C .
A.5.2 Load at the PMGi
Do not overload the PMGi. It will go on error.
A.5.3 Automatic start
The generator can start (depending on the remote control panel) by an external signal (atomatic start)
If you use this option make sure that the load is connected to the PMGi after the output has reached the nominal
230V / 50Hz and not to overload the PMGi (some electronic devices, such like air conditions, need an higher start
current). May use a relay which connect the load at 230V.
A.6 Status LED´s
When the PMGi is mounted on the right way, vertical with the lectric connection down. The LED´s from left to right
are:
Red - Yellow - Green
LED - Red
Red LED lights together with the green LED for the very first seconds (about 5 sec) after the
running of the engine. During this time no output is provided by the PMGi.
Red LED starts to blink when an overload condition is reched. During this time the green LED
continiues to light.
When an overload condition stays for too much time the red LED stops blinking and stays per-
manently switched on, while the green LED switch off.
LED-Yellow
Yellow LED lights together with the green LED when the output voltage becomes less than the
nominal voltage.
LED-Green
Green LED permanently lights alone when the PMGi output is available and it value stays in
the spacification
Table 1: Status LED´s