Maintenance Instructions
Page 58 Panda_6000i_System_eng_s01835.book.R01 - Chapter E: Maintenance Instructions
16.1.09
4. Open the ventilation screw located at
the fuel solenoid valve. The „START“
button must continue to be pressed,
whilst opening the screw. A large cloth
or Kleenex tissue must be laid beneath
the connection to prevent escaping
fuel running into the capsule. If the fuel
runs out without air bubbles, then the
ventilation screw can be closed. Only
then may the „START“ button be
released.
5. Switch the panel „OFF“.
Th i s pr oc e d ur e m us t b e r e pe a te d
several times,until fuel (nonporously)
withdraws perfectly at the ventilation screw.
Fig. E.3-3: Ventilation screw at the fuel solenoid valve
6. Pressing the starter button can now
start the machine. The machine should
start after a short period.
7. If this does not occur, then a connec-
ting nut fitted to the injection line must
be loosened and starting procedure
repeated. Retighten the washers after
successfully starting. The injection line
must be raised by several millimetres.
8. Switch main switch "OFF"
Fig. E.3-4: Injection nozzles
E.3.1 Replace of the fuel filter
Exchanging the filter, depending upon fuel
contamination, should take place after 300
operational hours at the very least. The
inlet must be clamped, before exchanging
the filter.
Remove the hoses from the used filter
and fasten them to the new filter. The
arrow on the filter housing indicates the
direction of the fuel flow. A clogged filter
causes a decreased power output of the
generator.
Fig. E.3.1-1: Fuel filter
10
17
Summary of Contents for Panda 6000i PMS
Page 9: ...Panda 6000i PMS 230V 50Hz 6kW Fischer Panda GmbH Panda 6000i Part 1 Generator Manual ...
Page 14: ...14 Socket wrench set Hexagon wrench keys ...
Page 18: ...18 Intentionally Blank ...
Page 92: ...Panda iControl Page 92 Chapter A Panda iControl Panel_iControl_eng fm Intentionally Blank ...