16
The electrical Installations may only be carried out by trained and
examined personnel!
The generator may not be taken into use with the cover removed.
The rotating parts (belt-pulley, belts, etc) must be covered and protected so that there is no danger to life and body!
If a sound insulation cover must be produced at the place of installation, then well-placed signs must show that the
generator can only be switched on with a closed capsule.
All servicing-, maintenance or repair work may only be carried out, when the motor is not running.
Electrical power: DANGER TO LIFE!
Electrical voltages above 48 volts (battery chargers greater than 36 volts) are always dangerous to
life). The rules of the respective regional authority must be adhered to. Only an electrician may
carry out installation of the electrical connections for safety reasons.
General safety references for the enterprise of a generator.
With all energized systems, with which the current is more than 50 Ampère, special safety precautions must be
made, in order to protect the environment of the components against fire.
It is to be ensured absolutely that at the battery a main switch in well accessible place is accommodated, so that with
danger of the main switches can be separated immediately. The main switch must be however also directly at the
battery installed. If this place is not well accessible, a power relay must be used instead of the main switch which can
be served manually, which can be served then if necessary from different places. The switches for the power relay
are to mark accordingly as main switches DC battery "with danger switch off!".
ATTENTION!
Do not connect the minus pole of the starter battery to the ground of the boat because of galvanic reason.
CAUTION!
Contact of the electrical contacts may be DANGER TO LIFE!
The PMGi cable must be secured at the generator and at the PMGi with appropriate safety devices.
The generator is also included into the CO
2
- fire-extinguishing system.
Fire protection measures
All construction units in the environment of energized parts, which carry more than 50 Amp., must be fire protection-
moderately secured.
All junction points at the energized parts must be examined on heating up regularly (infrared thermometers).